Control Systems
36
I
I
Individual control systems
4. ERV wired remote controller
MWR-VH12N
3) Description of parts
⑨
⑦
⑧
⑤
⑭
⑮
⑯
④
⑥
③
①
②
⑩
⑪
⑫
⑬
No.
Name
Description
①
Operation mode indicator
*OEJDBUFTDVSSFOUPQFSBUJPONPEFXIFOUIF&37JTPQFSBUJOH
)FBU&9#Z1BTT"VUP2VJFU
②
Timer indicator
Indicates when On timer is set.
Indicates when Off timer is set.
①
5JNFSNPEFo%JTQMBZTUIFTFUUJNFGPS0O0GGUJNFS .JONJOVUFT_.BYIPVST
②
(FOFSBMNPEFo%JTQMBZTSFNBJOJOHUJNFCFGPSF5JNFSGVODUJPOXJMMFYFDVUF
③
0VUJOHNPEFJOEJDBUPS
Indicates when outing mode is on.
④
'JMUFSDMFBOJOH QFSJPEJOEJDBUPS
Indicates when preset filter cleaning is required.
⑤
Fan speed indicator
Indicates current fan speed settings.
⑥
S-Plasma ion(SPI) indicator (optional)
Indicates when S-Plasma ion(SPI) function is on.
⑦
CO2 sensor indicator (optional)
*OEJDBUFTJOEPPS$0EFOTJUZXIFOUIFTFOTPSJTPO *GUIF&37JTPQFSBUJOH
⑧
Inspection/Lock/Restricted indicator
Indicates that inspection is required.
Indicates when an unavailable function which is not supported by indoor units is selected or
when the button is locked.
Indicates when all buttons are locked.
⑨
Exhaust hood/Centralized/External
JOUFSMPDLJOHDPOUSPMJOEJDBUPS
*OEJDBUFTXIFO&YIBVTUIPPE$FOUSBMJ[FE&YUFSOBMJOUFSMPDLJOHDPOUSPMJTPO
⑩
0O0GGCVUUPO
5PUVSO&37POPSPGG
⑪
0QFSBUJPONPEFCVUUPO
5PTFMFDUBOPQFSBUJPONPEF )FBU&9
J
By-pass
J
Auto
J
Quiet)
J
"WBJMBCMFPQFSBUJPONPEFJTBDDPSEJOHUP&377JFXNBTUFS
⑫
5JNFSCVUUPO
5PTFUTJNQMFPOPGGUJNFSPSFYUFSOBMJOUFSMPDLJOHEFMBZ
⑬
4FU$BODFMCVUUPO
5PTFUPSDBODFMUIFPQUJPO
J
Press and hold the button for over 3 seconds to cancel the timer.
⑭
'BOTQFFECVUUPO
5PTFMFDUUIFGBOTQFFETPGJOEPPSVOJUT
J
"WBJMBCMFGBOTQFFEEJGGFSTEFQFOEJOHPOUIFPQFSBUJPONPEFJOUIFGPMMPXJOHPSEFS-PX
J
Medium
J
High
J
5VSCP
J
Auto.
⑮
0VUJOH'JMUFSSFTFUCVUUPO
①
5PUVSOUIFPVUJOHNPEFPOPSPGG
②
5PUVSOUIFGJMUFSDMFBOJOHEJTQMBZPGG
J
Press and hold the button for over 3 seconds to turn off the filter cleaning display.
⑯
5JNFBEKVTUNFOUCVUUPO
5PNPWFUPUIFMBTUPSUIFOFYUJUFNTPSDIBOHFUIFTFUWBMVF
①
Press the button to increase or decrease the set time during the timer is set.
J
6QUPIPVST*ODSFBTFEFDSFBTFCZNJOVUFVOJU
J
0WFSIPVST*ODSFBTFEFDSFBTFCZIPVSVOJU
②
Press the button to increase or decrease the set time during external interlocking delay is set.
J
Set the time by 1 minute unit between 30 minutes and 1 hour.
Содержание MR-DH00
Страница 8: ...DVM CONTROL SYSTEMS 8...
Страница 75: ...75 III Integratedmanagementsystems DMS2 S NET3 76 111 1 2 I NTEGRATED M ANAGEMENT S YSTEMS...
Страница 93: ...I NTEGRATED M ANAGEMENT S YSTEMS 93 MJDL MJDL QQMJDBUJPO DPNQMFUFE Register control logic Control logic applied...
Страница 127: ...127 MFDUSJDJUZ NFUFS JOUFSGBDF NPEVMF 128 1 IV Powerdistributionsystem P OWER D ISTRIBUTION S YSTEM...
Страница 184: ...DVM CONTROL SYSTEMS 184 Uw G G U GGGX_ YWX TW TY GGG G aZ a...
Страница 197: ...197 MEMO Uw G G U GGGX YWX TW TY GGG G aZ a...