General Advice

The heat pump comes with a Samsung controller which looks like 
this, you should not use this or press the buttons, it is used for 
commissioning and fault diagnosing the system only.

On Youtube (search for freedom heat pumps) there are videos 
showing how to use the controller, faults etc.

Normally the remote controller will look like this: it will  show Zone, 
on SET 0.0°C and DHW set 48.0°C standard. The on off button will 
be lit up in white. This is normal.

If the system goes into fault, the screen will show a number at the 
bottom starting with E, for example E911 – A00. The green light 
will go out and a red light will flash. The engineer will want to know 
this number when you call.

Please avoid turning the unit off at the power supply especially 
in cold weather. If the unit is off and the weather is very cold, it 
cannot protect itself and your warranty will be at risk.

If the unit is off and the temperature outside is cold, it will 
automatically run the pump for a few minutes to stop freezing. 
In extreme weather, below -2°C the water pump will run 
continuously, you cannot stop this. 

Hot Water

On the right of the controller it will say DHW set 48°C standard, this means your unit is monitoring the cylinder temperature.

The unit is set up to maintain the water between 43 and 50°C for efficiency, this can be increased to operate between 53 and 60°C all 
the time if required.

As you use the water the heat pump will constantly top up the cylinder. The hot water cylinder has priority over the heating, if the 
cylinder temperature falls 5 degrees below its set point the unit will automatically switch to heating the cylinder. This should take less 
than an hour.

Once set temperature is achieved the unit will go back to heating the house. The hot water cylinder loses almost no heat (1/3 a degree 
an hour) if no hot water is used.

With if you want to heat the cylinder quickly press right so the DHW is high lit in blue press ok the screen will show the set temperature, 
you can adjust this here. It should be on 48°C. Press ok and the screen offers options of economic, standard, power and forced, scroll 
down 2 x to forced, press ok. This will heat the tank to set temperature immediately with the HP and Immersion together. It will return to 
standard after 1 hour.

An anti-legionella / disinfection operation will be completed at a 3am every Tuesday morning. The unit will heat the cylinder with the 
immersion to 60°C, the hot water will be hotter on a Wednesday morning than the rest of the week. If legionella is not completed this 

e919

 will flash on screen, you need to call an engineer to check it.

If you don’t require 24/7 hot water It is possible to time clock the hot water to reduce costs, the timer video on you tube will show you 
how to do this.

Handover of the System

Содержание MIM-E03CN

Страница 1: ...0 080 120 160RXYDEG and DGG Installation and Maintenance Manual With Pre Plumbed Cylinders 30 09 2019 19 24 07 October 2019 Greenway Energy Limited Unit 3 Colemeadow Road North Moons Moat Redditch Wor...

Страница 2: ...you are used to with a gas or oil boiler To add to this we run them in a weather compensation mode this means that the unit measures the outside temperature and adjusts the radiator temperature to su...

Страница 3: ...50 C for efficiency this can be increased to operate between 53 and 60 C all the time if required As you use the water the heat pump will constantly top up the cylinder The hot water cylinder has prio...

Страница 4: ...peration status display Displays the operation function settings and statuses 2 Operation On Off button LED display Turns the Air to Water Heat Pump power On Off 3 Up Down button Moves between items v...

Страница 5: ...ile running check the outdoor unit for damage debris the coil needs washing we recommend you use an approved EHS heat pump cleaning chemical your distributor will stock this Instructions are given on...

Страница 6: ...to the ground Dimensions Size 12 and 16 1420mm h 940mm w 330mm d 103kg Size 8 998mm h 940mm w 330mm d 75kg Size 5 798mm h 880mm w 310mm d 59kg The space around the unit is very important allow 300mm t...

Страница 7: ...feeds the tundish and drains You need to install an expansion vessel on the heat pump side and the heating side of the system and one onto the cylinder The 300l cylinder needs a floor area of 700 wide...

Страница 8: ...f you need Neutral use B19 Wiring Diagram Pre Plumbed Tank Sensor 15m long Don t cut this Immersion Heater Communication Cable 2 core 1mm 16Vdc Flow Switch 2m long You can extend this Power Input 16 A...

Страница 9: ...ter To avoid the immersion heater cutting out before the legionella function is complete you have to set the stat in the immersion heater to 70 C minimum on a Telford cylinder set it to 5 Check the ta...

Страница 10: ...ally add 2 on timers a day one at 3 00 am and one at 15 00 pm This stops nuisance tripping resets the unit after power cuts and insures the cylinder is hot 24 hours a day We don t normally set any off...

Страница 11: ...educed Glycol System If you want to reduce the amount of Glycol to be used in the system you can install a plate heat exchanger The heat exchanger needs to be suitably sized if in doubt please ask Hea...

Страница 12: ...sed Pump Z1 Pump HP H HW Power supply 240V 16 Amp for the 5kW 20 Amp for the 8kW 32 Amp for the 12kW 32 Amp for the 16kW F1 F2 L N Pump HP is wired Live to B8 and Neutral to B7 MAX pump power is 500W...

Страница 13: ...set it to 5 Check the tank sensor The blue tank sensor MUST be installed above the immersion heater and it must be securely fixed in the tank right into the back of the pocket I would use heat paste a...

Страница 14: ...ting 1 Press ok to wake the controller up 2 Press and v together for 6 seconds password shows you need to set 0202 by pressing 3 Press then twice twice twice then press OK 4 Press v 8 times to Field s...

Страница 15: ...ss adjust hour to 3 pm press ok Heating Hot Water Installation Field settings for Hot Water 11 Then v to 30 DHW press ok 3011 will be highlit Domestic hot water tank press OK 12 Press v to hysteresis...

Страница 16: ...ck to the normal screen Use of self test mode 1 Press OK to wake the controller up 2 Press and v together for 6 seconds password shows you need to set 0202 3 Press then twice twice twice then press OK...

Страница 17: ...erature and current temperature will show To adjust the temperature press and v set it to 48 C Press ok to switch between standard eco cold water and boost only used in emergency s The heat pump will...

Страница 18: ...together for 6 seconds password shows you need to set 0202 8 Press then twice twice twice then press OK 9 Press v 9 times to Self test mode press 10 You can see all the sensors on the unit at once Re...

Страница 19: ...o slowly through the system With the pump running test the flow rate see page 20 and 22 If your flow rate is less than recommended you need to turn up the pumps open any valves that might be closed cl...

Страница 20: ...must have no breaks or switches in it If the cable is ok it s possible one of the PCBs is at fault The hardest thing for an engineer to do is work out which end has the communication error In the midd...

Страница 21: ...the heat exchanger to the heat pump 20m separation on 22mm copper for the 5kW 20 m separation on 28mm copper for the 9kW 7 5m separation on 28mm copper for the 16kW If you use a low loss header inste...

Страница 22: ...ers If you are using more than one heat source heat pump boiler you MUST measure the heat produced by the heat pump and the electricity used This is essential for RHI The heat meter goes in the return...

Страница 23: ...ls F1 F2 to the control box terminals F1 F2 Use 2 core flex 0 5 1mm its 16V AC It must not have any breaks in it or switches Remote controller is normally installed next to the control box out of easy...

Страница 24: ...clock or a run signal from an under floor manifold B20 is permanently 240V AC The run signal goes into B22 When using multi zone heating systems on a header buffer or HEX When the stat is made it will...

Страница 25: ...2 smart electric meters are used Ideally it should measure the total draw for the heat pump outdoor and indoor unit combined The outdoor unit takes most of the current so in many installations it wil...

Страница 26: ...Coil Cylinder stat set at 55 C Pump HP H Z1 Z1 HW Multi Fuel 2 Heat Pumps Pump Z1 Header or Bu er Tank Heating Hot Water Heating Only Flow and returns pumped by field supplied pump Pump HP H Z1 Z1 HW...

Страница 27: ...or Heat Exchanger Pump HP Heating Pools Hybrid Fast Connect Combi Boiler Board is waterproof and mounts outside behind the heat pump Boiler must be set to run below 65 C To Heating Other Systems Poss...

Отзывы: