21

Starting the unit in heating mode

Press the left button so the Zone is highlit in blue, press the power button a temperature will show  
will show, the unit is automatic mode using an external run signal. Turn up your thermostats or 
underfloor heating to send a run signal to the unit, the display will change to set 0.0c the pump will 
start within 3 minutes. The compressor in the outdoor unit starts after 3 minutes, the pipework will 
begin to heat up. 

If you press the ok button, you can see the water outlet flow temperature rising.

If the outdoor unit doesn’t start after 5-minutes, see problems page.

Over time the unit will warm up, now check all the radiators or under floor loops are hot as well.

Starting the System in hot water mode

Clean the filter balls again.

Press return to get to the normal screen. With the zone hi lit in blue press the power button, heating 
will stop. Now press >  to highlight the DHW and press the power button again.

The DHW will start the display will show 48°C set standard

Press ok

The cylinder set temperature and current temperature will show.

To adjust the temperature press ^ and v set it to 48°C.

Press ok to switch between standard , eco (cold water) and boost only used in emergency’s.

The heat pump will start heating the cylinder if its colder than 43°C and will heat it up to 50°C then it 
will stop. The unit will take up to 6 minutes to start in Hot water mode, be patient 

When the unit is heating the cylinder, the HW valve will open but the heating valve will not close for 
40 seconds, this is normal.

Run test in hot water mode

Make a note of the hot water cylinder temperature, after 15 minutes of running check the hot water temperature again, it should have 
risen, again note the temperature. If the unit is running well it should heat the cylinder to 48°C without needing the immersion heater. 
Now clean the filter ball again.

The Water storage temperature is lower (48°C) than a normal cylinder. It’s important to check that any shower or bath mixers do not 
further reduce the water temperature. Using your thermometer check that the hot water comes out the tap

Now handover the system to the end user, see page 6-8, fill in the warranty card on page 4 and online. Your system is now fully 
commissioned, congratulations.

Starting the Unit

Содержание MIM-E03CN

Страница 1: ...0 080 120 160RXYDEG and DGG Installation and Maintenance Manual With Pre Plumbed Cylinders 30 09 2019 19 24 07 October 2019 Greenway Energy Limited Unit 3 Colemeadow Road North Moons Moat Redditch Wor...

Страница 2: ...you are used to with a gas or oil boiler To add to this we run them in a weather compensation mode this means that the unit measures the outside temperature and adjusts the radiator temperature to su...

Страница 3: ...50 C for efficiency this can be increased to operate between 53 and 60 C all the time if required As you use the water the heat pump will constantly top up the cylinder The hot water cylinder has prio...

Страница 4: ...peration status display Displays the operation function settings and statuses 2 Operation On Off button LED display Turns the Air to Water Heat Pump power On Off 3 Up Down button Moves between items v...

Страница 5: ...ile running check the outdoor unit for damage debris the coil needs washing we recommend you use an approved EHS heat pump cleaning chemical your distributor will stock this Instructions are given on...

Страница 6: ...to the ground Dimensions Size 12 and 16 1420mm h 940mm w 330mm d 103kg Size 8 998mm h 940mm w 330mm d 75kg Size 5 798mm h 880mm w 310mm d 59kg The space around the unit is very important allow 300mm t...

Страница 7: ...feeds the tundish and drains You need to install an expansion vessel on the heat pump side and the heating side of the system and one onto the cylinder The 300l cylinder needs a floor area of 700 wide...

Страница 8: ...f you need Neutral use B19 Wiring Diagram Pre Plumbed Tank Sensor 15m long Don t cut this Immersion Heater Communication Cable 2 core 1mm 16Vdc Flow Switch 2m long You can extend this Power Input 16 A...

Страница 9: ...ter To avoid the immersion heater cutting out before the legionella function is complete you have to set the stat in the immersion heater to 70 C minimum on a Telford cylinder set it to 5 Check the ta...

Страница 10: ...ally add 2 on timers a day one at 3 00 am and one at 15 00 pm This stops nuisance tripping resets the unit after power cuts and insures the cylinder is hot 24 hours a day We don t normally set any off...

Страница 11: ...educed Glycol System If you want to reduce the amount of Glycol to be used in the system you can install a plate heat exchanger The heat exchanger needs to be suitably sized if in doubt please ask Hea...

Страница 12: ...sed Pump Z1 Pump HP H HW Power supply 240V 16 Amp for the 5kW 20 Amp for the 8kW 32 Amp for the 12kW 32 Amp for the 16kW F1 F2 L N Pump HP is wired Live to B8 and Neutral to B7 MAX pump power is 500W...

Страница 13: ...set it to 5 Check the tank sensor The blue tank sensor MUST be installed above the immersion heater and it must be securely fixed in the tank right into the back of the pocket I would use heat paste a...

Страница 14: ...ting 1 Press ok to wake the controller up 2 Press and v together for 6 seconds password shows you need to set 0202 by pressing 3 Press then twice twice twice then press OK 4 Press v 8 times to Field s...

Страница 15: ...ss adjust hour to 3 pm press ok Heating Hot Water Installation Field settings for Hot Water 11 Then v to 30 DHW press ok 3011 will be highlit Domestic hot water tank press OK 12 Press v to hysteresis...

Страница 16: ...ck to the normal screen Use of self test mode 1 Press OK to wake the controller up 2 Press and v together for 6 seconds password shows you need to set 0202 3 Press then twice twice twice then press OK...

Страница 17: ...erature and current temperature will show To adjust the temperature press and v set it to 48 C Press ok to switch between standard eco cold water and boost only used in emergency s The heat pump will...

Страница 18: ...together for 6 seconds password shows you need to set 0202 8 Press then twice twice twice then press OK 9 Press v 9 times to Self test mode press 10 You can see all the sensors on the unit at once Re...

Страница 19: ...o slowly through the system With the pump running test the flow rate see page 20 and 22 If your flow rate is less than recommended you need to turn up the pumps open any valves that might be closed cl...

Страница 20: ...must have no breaks or switches in it If the cable is ok it s possible one of the PCBs is at fault The hardest thing for an engineer to do is work out which end has the communication error In the midd...

Страница 21: ...the heat exchanger to the heat pump 20m separation on 22mm copper for the 5kW 20 m separation on 28mm copper for the 9kW 7 5m separation on 28mm copper for the 16kW If you use a low loss header inste...

Страница 22: ...ers If you are using more than one heat source heat pump boiler you MUST measure the heat produced by the heat pump and the electricity used This is essential for RHI The heat meter goes in the return...

Страница 23: ...ls F1 F2 to the control box terminals F1 F2 Use 2 core flex 0 5 1mm its 16V AC It must not have any breaks in it or switches Remote controller is normally installed next to the control box out of easy...

Страница 24: ...clock or a run signal from an under floor manifold B20 is permanently 240V AC The run signal goes into B22 When using multi zone heating systems on a header buffer or HEX When the stat is made it will...

Страница 25: ...2 smart electric meters are used Ideally it should measure the total draw for the heat pump outdoor and indoor unit combined The outdoor unit takes most of the current so in many installations it wil...

Страница 26: ...Coil Cylinder stat set at 55 C Pump HP H Z1 Z1 HW Multi Fuel 2 Heat Pumps Pump Z1 Header or Bu er Tank Heating Hot Water Heating Only Flow and returns pumped by field supplied pump Pump HP H Z1 Z1 HW...

Страница 27: ...or Heat Exchanger Pump HP Heating Pools Hybrid Fast Connect Combi Boiler Board is waterproof and mounts outside behind the heat pump Boiler must be set to run below 65 C To Heating Other Systems Poss...