Deciding on Where to Install the Air Conditioner (Continued)
P
REPARING THE
I
NSTALLATION
E-
8
1, 220-240, 50
Indoor unit
Outdoor unit
Power supply
Ø, V, Hz
✴✴
026/030/035/052
✴✴
MH070FXEA4B
MH080FXEA4B
✴✴
026/030/035
✴✴
✴✴
052
✴✴
Liquid
1/4”
Gas
3/8”
1/2”
Unit
Outside diameter
◗
Piping outside diameter
300 mm
minimum
600 mm
minimum
600 mm
minimum
300 mm
minimum
Main power switch
(h)
(H)
A
B
C
D
◆
MH070FXEA4B/MH080FXEA4B
◗
Piping length and the height
Dimension
Composition
1 Room max
length
25 m
A, B, C, D
4 Room total max
length
70 m
A + B + C + D
Max height between
indoor unit & outdoor unit
15 m
(H)
Max height between
indoor units
7.5 m
(h)
Make at least one round :
It will reduce noise and vibration.
◗
System can work with one indoor unit connected,but it is recommended that the TOTAL number of
indoor unit suggested by manufacturer are connected to obtain the maximum performance.
❊
The appearance of the unit may be different from the diagram depending on the model.
3m as minimum pipe length. It will reduce noise
and vibration.
If just one indoor unit is connected this value
must be increased up to 7.5m.