Piping length and the height
◗
System can work with one indoor unit connected,but it is recommended that the TOTAL number of
indoor unit suggested by manufacturer are connected to obtain the maximum performance.
Dimension
Composition
1 Room max
length
20 m
A, B
2 Room total max
length
30 m
A + B
Max height between
indoor unit & outdoor unit
15 m
(H)
Max height between
indoor units
7.5 m
(h)
❊
The appearance of the unit may be different from the diagram depending on the model.
3m as minimum pipe length. It will reduce noise
and vibration.
If just one indoor unit is connected this value
must be increased up to 7.5m.