Connecting the Connection Cord
Wiring Diagram
Indoor Unit
Outdoor Unit
Cable H07 RN-F
Communication
Power
◆
Always remember to connect the refrigerant pipes before performing the electric connections.
When disconnecting the system,always disconnect the electric cables before disconnecting the
refrigerant pipes.
◆
Always remember to connect the air conditioner to the grounding system before performing the
electric connections.
C
C
C
C
A
A
A
A
U
U
U
U
T
T
T
T
II
II
O
O
O
O
N
N
N
N
The indoor unit is powered by the outdoor unit by means of a H07 RN-F
connection cable (or a more power model), with insulation in synthetic
rubber and jacket in polychloroprene(neoprene), in accordance with the
requirements of standard EN 60335-2-40.
Remove the screw on the electrical component box and remove the cover
plate.
1
Route the connection cord through the side of the indoor unit and connect
the cable to terminals; refer to the figure below.
2
Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
3
Reassemble the electrical component box cover, carefully tightening the
screw.
4
Power supply
Communication
220-240V~, 50Hz
-
1.0 mm
2
or more, 3 wires
1.0 mm
2
or more, 2 wires
1Km
1Km
Indoor-Outdoor units
Power (±10%)
Power cable
Max. Length
❈
Size of the cables used to interconnect the indoor and outdoor units.