SAMSUNG DCS
PROGRAMMING
TECHNICAL MANUAL
SECTION
Page 273 of 287
Updated I&M
May 2002
Dial 2
Even
STOP BIT
Dial 1
1 bit
Dial 2
2 bit
PROGRAM KEYS
UP & DOWN
Used to scroll through options
KEYPAD
Used to enter selections
SOFT KEYS
Move cursor left and right
SPK
Used to store data and advance to next MMC
HOLD
Used to clear entry (when valid)
ACTION
DISPLAY
1.
Press TRSF 804
SYS I/OPORT : 1
Display shows
SERVICE : PC - MMC
2.
Enter in desired port via dial
SYS I/OPORT : 2
key pad (eg., 2)
SERVICE : SMDR
OR
Press UP or DOWN key to make selection
and press RIGHT soft key to move cursor
3.
Enter parameter desired via dial key pad
SYS I/OPORT : 2
(eg., 7) from the above option list
SIM PAIR : NONE
OR
Press UP or DOWN key to make selection
and press RIGHT soft key to move cursor
4.
Enter in station number of desired SIM
SYS I/OPORT : 2
via dial keypad (eg., 2902)
SIM PAIR : 2902
OR
Press UP or DOWN key to display SIM(s)
and press RIGHT soft key to return to step 2
5.
Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA
:
SERVICE
PORT 1
PCMMC
PORT 2
SMDR
BAUD RATE
9600 BPS
CHAR LENGTH
8 BITS
PARITY
NONE
RETRY COUNT
03
STOP BIT
1 BIT
WAIT TIME
PORT 1
3000 msec
WAIT TIME
PORT 2
300 sec
RELATED ITEMS:
PCMMC SECTION
MMC 725 SMDR