SAMSUNG DCS
PROGRAMMING
TECHNICAL MANUAL
SECTION
Page 135 of 287
Updated I&M
May 2002
CO CLEAR TIME
30 SEC
0–255 SEC
CO CONFIRM TIME
003 MIN
CO–CO DISCONNECT
20 MIN
0–255 MIN
CONFER TONE INT
9900 MS
100-9900 MS
CONFIRM TONE TM
1000 MS
100–2500 MS
CRD TONE INT TIME
030 SEC
DATA EXIT TIME
010 SEC
DATA OTASK TIME
0100 MS
DIAL PASS TIME
5 SEC
1–25 SEC
DISA DISCONNECT
30 MIN
1–255 MIN
DISA LOCK OUT/TM
30 MIN
1–255 MIN
DISA NOANS DISC
DISA PASS CHECK
30 MIN
1–255 MIN
DISPLAY DELAY TM
3 SEC
1–255 SEC
DOOR LOCK RELEASE
500 MS
100–2500 MS
DOOR RING DETECT
50 MS
10–250 MS
DOOR RING OFF TM
30 SEC
1–255 SEC
E-HOLD RECALL TM
45 SEC
0–255 SEC
EXT.FWD DELAY TM
10 SEC
1–255 SEC
FIRST DIGIT TIME
10 SEC
1–255 SEC
HOOK FLASH MAX TM
180 MS
20–2500 MS
HOK FLASH MIN TM
70 MS
20–2500 MS
HOOK OFF TIME
200 MS
100–2500 MS
HOOK ON TIME
1000 MS
20–2500 MS
INQUIRY RELEASE
30 SEC
1–255 SEC
INTER DIGIT TIME
10 SEC
1–255 SEC
KMMC LOCK OUT TM
30 SEC
10–255 SEC
LCR ADVANCE TIME
5 SEC
1–255 SEC
LCR INTER DIGIT
5 SEC
1–255 SEC
MCL DELAY TIME
4 SEC
1-8 SEC
OFF HOOK RING INT
15 SEC
1–255 SEC
OFF HOOK SELECT
5 SEC
1–255 SEC
OHVA ANSWER TIME
10 SEC
1–255 SEC
OVERLAP INT DGT
7 SEC
1 - 15 SEC
PAGE TIME OUT
20 SEC
1–255 SEC
PAGE TONE TIME
500 MS
100–2500 MS
PARK RCALL TIME
45 SEC
0–255 SEC
PC-MMC LOCK OUT
5 MIN
1–60 MIN
POWER DOWN TIME
200 MS
100–2500 MS
RECALL DISCONECT
45 MIN
1–255 MIN
RECALL WAIT TIME
15 SEC
1–255 SEC
SMDR START/DP
30 SEC
1–255 SEC
SMDR START /DTMF
15 SEC
SYS HOLD RECALL
45 SEC
0-255 SEC
TRANSFER RECALL
20 SEC
0-255 SEC
UCDS AUDIO ALARM
0 SEC
0-990 SEC
UCDS VISUAL ALAM
0 SEC
0-990 SEC
VOICE DIAL DELAY
8 SEC
05-15 SEC
R/D RING ON
15 SEC
0-99 SEC
R/D SIGNAL ON
02 SEC
0-99 SEC
VMS UCD MSG TIME
05 SEC
0-99 SEC
PERI UCD STATS
05 MIN
0-99 MIN
TIMER DESCRIPTIONS
AA INT DGT TIME:
This timer controls the grace period between dialling valid digits before transferring call to
INVLID DEST as set in MMC 733 on a per-plan basis.
AA NO ACT TIME:
If no digits are received by the AA module, this timer will expire and transfer the call to the
destination set in MMC 733 NO ACT DEST.