CONTENTS
3.4
3.6
KEYSET LED INDICATIONS
CONDITION
LED COLOR
LED ON
LED OFF
LINE IDLE
OFF
–
OFF
LINE IN USE
RED/GREEN
STEADY
–
RECALL
AMBER
500 ms
500 ms
CALL ON HOLD
RED/GREEN
500 ms
500 ms
RINGING C.O. CALL
GREEN
100 ms
100 ms
RINGING INTERNAL CALL
GREEN
100 ms
100 ms
DND INDICATION
RED
112 IPM for 500 ms
500 ms
OPERATOR CALLS
RED
100 ms
100 ms
ANS/RLS (DND)*
RED
112 IPM for 500 ms
500 ms
ANS/RLS (HDSET MODE)
RED
STEADY
–
TRSF (FORWARD ALL)
RED
STEADY
–
*Overrides headset mode
3.7
RESERVE POWER DURATION ESTIMATES
(in minutes)*
UPS CAPACITY IN VOLT AMPS (VA)
250
400
450
600
900
1250
2000
1
1
5
13
24
31
47
75
180
1
2
8
10
24
40
70
2
2
8
10
24
40
70
2
3
13
22
35
2
4
10
13
25
*These are approximate values based on average UPS run times. Specific UPS devices,
due to their internal contruction, can have greater or lesser values.
No. of
Cabs.
No. of
PCUs
Содержание DCS 400SI