background image

E-

6

Deciding Where to Install the Indoor Unit (continued)

Drawing of the indoor unit

Unit : mm

No.

Name

"A"Model

"B"Model

1

Liquid pipe connection

CH052EAMC/CH070EAM1C:ø6.35(1/4")

CH070EAMC:ø9.52(3/8")

CH094EAMC:ø9.52(3/8")

ø9.52(3/8")

2

Gas pipe connection

CH052EAMC:ø12.7(1/2")

CH070EAM(1)C:ø15.88(5/8")

CH094EAMC:ø15.88(5/8")

ø19.05(3/4")

3

Drain pipe connection

4

Power supply connection

5

Air discharge grille

6

Air suction grille

950

05

9

242

44

3

81

2

14

66

1

46

06

1

322

246

305

09

1

840

57

57

80

2

75

4

14

89

2

00

2

322

242

246

305

46

06

1

09

1

840

01

3

03

2

00

1

08

260

25

25

290

57

57

85

1

83

1

86

25

25

260

290

80

2

Branch duct

connection

mm

00

01

er

o

m r

o

 d

eri

uq

e

R

ec

ap

s

1

elb

ats

ujd

A87

elb

ats

ujd

A8

52

mm

00

01

er

o

m r

o

 d

eri

uq

e

R

ec

ap

s

Branch duct

connection

“A” Model: CH052/070/094EAMC

                   CH070EAM1C

“B” Model: CH105/140EAMC

860

~

690 

(Ceiling opening)

699

(Suspension position)

86

0

~

69

0

(C

ei

lin

op

en

in

g)

76

6

(S

us

pe

ns

io

n)

Содержание CH EAMC Series

Страница 1: ...ENGLISH System Air Conditioner Cooling and Heating E S F I P D G R DB98 26330A 4 CH EAM 1 C Series ENGLISH ESPA OL FRAN AIS ITALIANO PORTUGU S DEUTSCH E HNIKA RUSSIAN INSTALLATION MANUAL...

Страница 2: ...s outside impacts and so on Installing the unit If the power cord of this air conditioner is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order t...

Страница 3: ...Connecting the Refrigerant Pipe 9 Cutting Flaring the Pipes 10 Performing Leak Test Insulation 11 Connecting the Cables to the Outdoor Unit 11 Drainpipe and Drain Hose Installation 12 Connecting the C...

Страница 4: ...aline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions first consult your dealer Accessories The following accessories are supplied with th...

Страница 5: ...indoor unit on a ceiling that can support its weight Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indo...

Страница 6: ...e 6 Air suction grille 950 0 5 9 242 4 4 3 8 1 2 1 4 6 6 1 4 6 0 6 1 322 246 305 0 9 1 840 57 57 8 0 2 7 5 4 1 4 8 9 2 0 0 2 322 242 246 305 4 6 0 6 1 0 9 1 840 0 1 3 0 3 2 0 0 1 0 8 260 25 25 290 57...

Страница 7: ...bles and install the front panel Ensure that the ceiling is strong enough to support the weight of the indoor unit Before hanging the unit test the strength of each attached suspension bolt If the len...

Страница 8: ...piping Note On delivery the indoor unit is loaded with refrigerant gas All this gas must therefore be purged before connecting the assembly piping To purge the inert gas proceed as follows Unscrew th...

Страница 9: ...refrigerant pipe to protect the condensate water on the outside of pipe falling onto the floor and the efficiency of the unit will be better 2 Cut off any excess foam insulation 3 Be sure that there m...

Страница 10: ...ipe and modify the flare 4 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring 5 Align the pipes and tighten the flare nuts first manually and then...

Страница 11: ...tightly against body without any gap No gap NBR T13 0 or thicker Connecting the Cables to the Outdoor Unit Two electric cables must be connected to the outdoor unit The connection cord connecting the...

Страница 12: ...that the indoor unit is level with the ceiling by using the leveler Air ventilation Ceiling Do not give the hose and upward gradient after the connection port This will cause water to flow backwards...

Страница 13: ...onfirm that the water flows out through the drain hose 3 Reassemble the cover drain pump 4 You can check the drainage only when the air conditioner is in cool mode Note If you do not pour water inside...

Страница 14: ...h the ceiling the hole on the wall 3 Reassemble the electrical component box cover carefully tightening the screw 4 Wiring Diagram Note 1 Connect the Connection Cord as seen in picture and the torque...

Страница 15: ...ntralized controller 4 If you install optional accessories such as the wired remote controller cen tralized controller etc see an appropriate installation manual 5 If an optional accessory is not inst...

Страница 16: ...component box cover For your safety you must install the safety net For details about installing the panel refer to the manual for the panel Fix the safety net to the electric component cover box wit...

Страница 17: ...ture sensor Error of the condensor temperature sensor Error of the discharge temperature sensor 1 No communication for 2 minutes between indoor units Communication error for more than 2 minutes 2 Indo...

Страница 18: ...perature discharge 5 Error of reverse phase 6 Compressor down due to 6 th detection of freezing X LED Display On Flickering X Off If you turn off the air conditioner when the LED is flickering the LED...

Страница 19: ...ure sensor Open Short Error of condensor temperature sensor Open Short Error of discharge temperature sensor Open Short System down caused by communication error after completion of tracking Mismatchi...

Страница 20: ...e joint 1 Owner s instructions 1 Installation manual 1 Wireless Remote Controller Accessories Wireless remote controller 1 Battery 2 Remote control holder 1 STS 2S 2x10 tapped screw 2 Owner s instruct...

Страница 21: ...Scheduler Accessories Cable tie 2 Cable clamp 2 M4x16 tapped screw 4 Owner s instructions 1 Installation manual 1 7 day Scheduler 1 Transmitter Accessories Transmitter power cable 1 Transmitter commun...

Страница 22: ...E 22 MEMO...

Страница 23: ...ENGLISH E 23...

Страница 24: ......

Отзывы: