Safety Precautions

The following safety precautions must be taken when using your air conditioner.

WARNING

 

 

The unit should not be installed by the user. Ask the dealer or autho-

rized company to install the units except room air conditioners for the 

U.S.A and Canada area.

 

 

If the unit is installed improperly, water leakage, electric shock or fire 

may result.  

 

 

Mount with the lowest moving parts at least 2.5 m above the floor or 

grade level. (If applicable)

   

The manufacturer does not assume responsibility for accidents or injury 

caused by an incorrectly installed air conditioner. If you are unsure about 

installation, contact an installation specialist.

 

 When installing the built-in type air conditioner, keep all electrical 

cables such as the power cable and the connection cord in pipe, ducts, 

cable channels e.t.c to protect them against liquids, outside impacts 

and so on.

Installing the unit

 

 If the power cord of this air conditioner is damaged, it must be replaced 

by the manufacturer, its service agent or similarly qualified persons in 

order to avoid a hazard.

  

The unit must be plugged into an independent circuit if applicable or  

connect the power cable to the auxiliary circuit breaker. An all pole  

disconnection from the power supply must be incorporated in the fixed 

wiring with a contact opening of >3mm. 

 

 Do not use an extension cord with this product.

  

If the unit is equipped with a power supply cord and a plug, the plug 

must be accessible after installation.

 

 The air conditioner must be installed in accordance with national wiring  

regulations and safety regulations wherever applicable.

Power supplyline,
fuse or circuit breaker

Risk of electric shock. • Can cause injury or death. • Disconnect all
remote electric power supplies before servicing, installing or cleaning.
• This must be done by the manufacturer or its service agent or a similar
 qualified person in order to avoid a hazard.

Содержание CH EAMC Series

Страница 1: ...ENGLISH System Air Conditioner Cooling and Heating E S F I P D G R DB98 26330A 4 CH EAM 1 C Series ENGLISH ESPA OL FRAN AIS ITALIANO PORTUGU S DEUTSCH E HNIKA RUSSIAN INSTALLATION MANUAL...

Страница 2: ...s outside impacts and so on Installing the unit If the power cord of this air conditioner is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order t...

Страница 3: ...Connecting the Refrigerant Pipe 9 Cutting Flaring the Pipes 10 Performing Leak Test Insulation 11 Connecting the Cables to the Outdoor Unit 11 Drainpipe and Drain Hose Installation 12 Connecting the C...

Страница 4: ...aline air Machine oil Sulphide gas Special environmental conditions If you must install the unit in such conditions first consult your dealer Accessories The following accessories are supplied with th...

Страница 5: ...indoor unit on a ceiling that can support its weight Maintain sufficient clearance around the indoor unit Make sure that the water dripping from the drain hose runs away correctly and safely The indo...

Страница 6: ...e 6 Air suction grille 950 0 5 9 242 4 4 3 8 1 2 1 4 6 6 1 4 6 0 6 1 322 246 305 0 9 1 840 57 57 8 0 2 7 5 4 1 4 8 9 2 0 0 2 322 242 246 305 4 6 0 6 1 0 9 1 840 0 1 3 0 3 2 0 0 1 0 8 260 25 25 290 57...

Страница 7: ...bles and install the front panel Ensure that the ceiling is strong enough to support the weight of the indoor unit Before hanging the unit test the strength of each attached suspension bolt If the len...

Страница 8: ...piping Note On delivery the indoor unit is loaded with refrigerant gas All this gas must therefore be purged before connecting the assembly piping To purge the inert gas proceed as follows Unscrew th...

Страница 9: ...refrigerant pipe to protect the condensate water on the outside of pipe falling onto the floor and the efficiency of the unit will be better 2 Cut off any excess foam insulation 3 Be sure that there m...

Страница 10: ...ipe and modify the flare 4 Check that the flaring is correct referring to the illustrations below for examples of incorrect flaring 5 Align the pipes and tighten the flare nuts first manually and then...

Страница 11: ...tightly against body without any gap No gap NBR T13 0 or thicker Connecting the Cables to the Outdoor Unit Two electric cables must be connected to the outdoor unit The connection cord connecting the...

Страница 12: ...that the indoor unit is level with the ceiling by using the leveler Air ventilation Ceiling Do not give the hose and upward gradient after the connection port This will cause water to flow backwards...

Страница 13: ...onfirm that the water flows out through the drain hose 3 Reassemble the cover drain pump 4 You can check the drainage only when the air conditioner is in cool mode Note If you do not pour water inside...

Страница 14: ...h the ceiling the hole on the wall 3 Reassemble the electrical component box cover carefully tightening the screw 4 Wiring Diagram Note 1 Connect the Connection Cord as seen in picture and the torque...

Страница 15: ...ntralized controller 4 If you install optional accessories such as the wired remote controller cen tralized controller etc see an appropriate installation manual 5 If an optional accessory is not inst...

Страница 16: ...component box cover For your safety you must install the safety net For details about installing the panel refer to the manual for the panel Fix the safety net to the electric component cover box wit...

Страница 17: ...ture sensor Error of the condensor temperature sensor Error of the discharge temperature sensor 1 No communication for 2 minutes between indoor units Communication error for more than 2 minutes 2 Indo...

Страница 18: ...perature discharge 5 Error of reverse phase 6 Compressor down due to 6 th detection of freezing X LED Display On Flickering X Off If you turn off the air conditioner when the LED is flickering the LED...

Страница 19: ...ure sensor Open Short Error of condensor temperature sensor Open Short Error of discharge temperature sensor Open Short System down caused by communication error after completion of tracking Mismatchi...

Страница 20: ...e joint 1 Owner s instructions 1 Installation manual 1 Wireless Remote Controller Accessories Wireless remote controller 1 Battery 2 Remote control holder 1 STS 2S 2x10 tapped screw 2 Owner s instruct...

Страница 21: ...Scheduler Accessories Cable tie 2 Cable clamp 2 M4x16 tapped screw 4 Owner s instructions 1 Installation manual 1 7 day Scheduler 1 Transmitter Accessories Transmitter power cable 1 Transmitter commun...

Страница 22: ...E 22 MEMO...

Страница 23: ...ENGLISH E 23...

Страница 24: ......

Отзывы: