SAMSUNG ELECTRONICS
9-2-7 Operation condition secession error
Indoor display
7 SEG DISPLAY
DESCRIPTION
C440
Prohibit Operation Condition Error (Heating)
C441
Prohibit Operation Condition Error (Cooling)
Outdoor display
Operation condition secession
: LAMP ON
: LAMP OFF
: LAMP BLINK
1. Checklist :
1) Check the temperature around the outdoor unit.
2. Troubleshooting procedure
Restart after power off
Is the operation condition secession
error appeared again?
* Heating mode *
Is the outdoor temperature over 40 or
under -30 ?
* Cooling mode *
Is the outdoor temperature under -7
NO
Terminate the service
YES
YES
The temperature condition is too poor to operate.
Wait until temperature is changed