oc
edur
e
Installation Procedure
Step 1 Checking and preparing
accessories
The following accessories are supplied with the indoor unit.
The type and quantity may differ depending on the
specifications.
Installation plate
Installation manual
User manual
PE indoor unit cover
Step 2 Selecting the installation
location
Indoor Unit
•
Where airflow is not blocked.
•
Where cool air can be distributed throughout the room.
•
Install the refrigerant piping length and the height
difference of both indoor and outdoor units as
indicated in the installation diagram.
•
Wall that prevents vibration and is strong enough to
hold the product weight.
•
Out of the direct sunlight .
•
1m or more away from the TV or radio (to prevent
the screen from being distorted or noise from being
generated).
•
As far away as possible from fluorescent and
incandescent lights (so that the remote control can be
operated well).
•
A place where the air filter can be replaced easily.
CAUTION
•
Avoid the following places to prevent malfunction of
the unit
– Where there is machine oil
– Salty environment such as the seaside areas
– Where sulfide gas exists
– Other special atmosphere areas
Space requirements for installation & service
Observe the clearances and maximum lengths as seen in
the picture below when installing the air conditioner.
100 mm or more
You can select the direction of draining.
(left or right)
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl tape.
Refer to page 17 for further details.
125 mm
or more
125 mm
or more
NOTE
•
The appearance of the unit may be different from the
diagram depending on the model.