12. Capacity Table
Combination
(Capacity Index)
Combination
(Total)
Combination
(%)
Outdoor
Temperature
(℃,DB)
Indoor Temperature(℃, DB)
14
16
18
20
21
22
24
TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW)
2500 2500 2500
7500
144%
-15
3.61
1.11
3.49
1.13
3.39
1.14
3.35
1.15
3.31
1.16
3.23
1.17
3.17
1.18
-10
4.32
1.17
4.20
1.19
4.09
1.20
4.04
1.21
4.00
1.22
3.92
1.23
3.85
1.24
-5
5.03
1.23
4.91
1.25
4.79
1.26
4.74
1.27
4.69
1.28
4.61
1.29
4.53
1.30
0
5.75
1.29
5.62
1.31
5.50
1.32
5.44
1.33
5.39
1.34
5.30
1.35
5.21
1.36
2
6.04
1.31
5.90
1.33
5.78
1.35
5.72
1.35
5.67
1.36
5.57
1.38
5.49
1.39
7
6.61
1.35
6.47
1.37
6.34
1.39
6.30
1.40
6.23
1.41
6.12
1.43
6.03
1.44
10
7.19
1.40
7.04
1.42
6.91
1.44
6.84
1.45
6.79
1.46
6.68
1.47
6.58
1.49
15
7.91
1.46
7.75
1.48
7.61
1.50
7.55
1.51
7.49
1.52
7.37
1.53
7.27
1.55
2500 2500 3500
8500
163%
-15
3.61
1.05
3.49
1.06
3.39
1.08
3.35
1.09
3.31
1.09
3.23
1.10
3.17
1.11
-10
4.32
1.10
4.20
1.12
4.09
1.14
4.04
1.14
4.00
1.15
3.92
1.16
3.85
1.17
-5
5.03
1.16
4.91
1.18
4.79
1.19
4.74
1.20
4.69
1.21
4.61
1.22
4.53
1.23
0
5.75
1.21
5.62
1.23
5.50
1.25
5.44
1.25
5.39
1.26
5.30
1.28
5.21
1.29
2
6.04
1.23
5.90
1.25
5.78
1.27
5.72
1.28
5.67
1.28
5.57
1.30
5.49
1.31
7
6.61
1.28
6.47
1.30
6.34
1.31
6.30
1.32
6.23
1.33
6.12
1.34
6.03
1.36
10
7.19
1.32
7.04
1.34
6.91
1.36
6.84
1.37
6.79
1.37
6.68
1.39
6.58
1.40
15
7.91
1.37
7.75
1.39
7.61
1.41
7.55
1.42
7.49
1.43
7.37
1.45
7.27
1.46
NOTE
•
Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).
•
Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).
•
The above is the value for connecting with the following indoor units.
- 2000, 2500, 3500, 5000W class : AR07TXFCAWKNEU, AR09TXFCAWKNEU, AR12TXFCAWKNEU, AR18TXEAAWKNEU
•
Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 5m / - Level difference : 0m
•
The total ability of connected a indoor unit is up to 7.5kW
•
It is impossible to connect the indoor unit for one room only.
•
This data is reference data for temperature capacity trend.