Testing the drainage
You should test the drainage after completing the
installation.
Prepare a little water about 2.0 liter.
1. Remove two screws on the cover drain pump
and pull out the cover.
2. Pour water into the indoor unit as shown in
figure.
NOTE
:
◆
If you do not pour water inside the water
supply intake, water may spill from the indoor
unit.
3. Confirm that the water flows out through the
drain hose.
NOTE
:
◆
You can check the drainage only when the air
conditioner is turned on.
4. Reassemble the cover drain pump and the
screws.
4-5-7 Connecting the Indoor Unit Assembly
Piping
There are two refrigerant pipes of differing diameters:
• A smaller one(9.52mm, 3/8") for the liquid refrigerant
• A larger one(15.88mm, 5/8") for the gas refrigerant
• The thickness of tube should not less than 1.0mm.
• The inside of copper tube must be clean & has no
dust.
The connection procedure for the refrigerant pipes
varies according to the exit position of the pipes from
the indoor unit, as seen when facing the indoor in the
"A" side.
• Liquid refrigerant port
• Gas refrigerant port
1. Remove the protection caps
on the pipes and connect
the assembly pipes to each
pipe, tightening the nuts,
first manually and then
with a wrench, a spanner
applying the following
torque.
Outer Diameter
Torque (kgf
•
cm)
1
9.52 mm (3/8")
300
15.88 mm (5/8")
750
Cover drain pump
Liquid refrigerant port
Gas refrigerant
port
A
00152-OIAIN-5 2/1/01 1:56 PM Page 4-29
Содержание ACH1800E
Страница 3: ...1 2 Samsung Electronics MEMO ...
Страница 11: ...Samsung Electronics Product Specifications 2 8 Centralized Controller ...
Страница 17: ...3 4 Micro Computer Block Diagram Cassette Indoor 3 6 Samsung Electronics ...
Страница 18: ...3 5 Micro Computer Block Diagram Outdoor Samsung Electronics 3 7 ...
Страница 19: ...3 8 Samsung Electronics MEMO ...
Страница 69: ...4 50 Samsung Electronics MEMO ...
Страница 75: ...5 6 Samsung Electronics Disassembly and Reassembly No Part name Procedures Picture Fan and motor Pump ...
Страница 76: ...Samsung Electronics 5 7 Disassembly and Reassembly No Part name Procedures Picture Pump ...
Страница 108: ...Samsung Electronics 6 21 MEMO ...
Страница 119: ...7 11 Samsung Electronics MEMO ...
Страница 125: ...8 6 Samsung Electronics MEMO ...
Страница 126: ...9 1 9 PCB Diagrams Samsung Electronics 9 1 Main PCB 9 1 1 Indoor Unit 18K 24K ...
Страница 129: ...Samsung Electronics 9 4 Indoor Unit 18K 24K 36K 44K ...
Страница 132: ...9 7 Samsung Electronics 9 1 2 Outdoor Unit 18K 24K ...
Страница 134: ...9 9 Samsung Electronics Outdoor Unit 18K 24K 36K 44K ...
Страница 137: ...9 12 Samsung Electronics MEMO ...
Страница 138: ...10 Wiring Diagrams 10 1 Indoor Unit 18K 24K Samsung Electronics 10 1 CASSETTE TYPE AIRCONDTIONER ...
Страница 139: ...10 2 Samsung Electronics 36K 44K Wiring Diagrams CASSETTE TYPE AIRCONDTIONER ...
Страница 140: ...10 2 Outdoor Unit 18K 24K Samsung Electronics 10 3 BUILT IN AIRCONDITIONER CODE NO DB68 00866A ...
Страница 141: ...10 4 Samsung Electronics 36K 44K Wiring Diagrams BUILT IN AIRCONDITIONER CODE NO DB68 00866A ...
Страница 142: ...11 Schematic Diagrams 11 1 Wired Remote Controller Samsung Electronics 11 1 ...
Страница 143: ...11 2 Centralized Controller 11 2 Samsung Electronics ...
Страница 144: ...11 3 Indoor Unit 18K 24K Samsung Electronics 11 3 ...
Страница 145: ... Indoor Unit 36K 44K 11 4 Samsung Electronics ...
Страница 146: ...11 4 Outdoor Unit 18 24K Samsung Electronics 11 5 ...
Страница 147: ... Outdoor Unit 36K 44K 11 6 Samsung Electronics ...
Страница 148: ...Samsung Electronics 11 7 MEMO ...
Страница 150: ...ELECTRONICS Samsung Electronics Co Ltd Jun 2000 Printed in Korea Code No DB81 00152A 4 ...