Mounting position
conditions (size and pressure rating of
the pipeline, medium temperature etc.).
5.2
Checking the installation
conditions
5.2.1 Mounting position
Î
Install the regulator with the actuator
housing suspended downward (with port
C facing upward) in horizontal pipelines
(see Fig. 4).
Î
Make sure the correct direction of flow is
used for the body design and the intend
-
ed use.
Pressure build-up regulator
with safety
function
Direction of flow from port
A
to port
B
Excess pressure valve:
Direction of flow from port
B
to port
C
The ports
A
and
B
are marked on the
body.
Î
Install the regulator free of stress.
Î
Make sure that the regulator remains
freely accessible after the plant has been
completed.
Do not attach supports directly to the regula-
tor.
NOTICE
!
NOTICE
!
A
B
C
Standard mounting posi
-
tion
For gases, liquids and
steam
Not permissible
Not permissible
Fig. 4:
Mounting position
5.2.2
Shut-off valves
Install a hand-operated shut-off valve (6.1
and 6.2) both upstream of the strainer and
downstream of the regulator to be able to
shut down the plant for cleaning and mainte
-
nance and when the plant is not used for
longer periods of time.