15
Section 4 |
installation
4.9 ReMote contRoL
remote Control Model No. SSW-r1-12b has been provided only for Model SSW-1000-12A, SSW-1500-12A
and SSW-2000-12A. Please refer to separate manual for the above remote.
!
cAUtIon!
When wiring remote Control SSW-r1-12b, the oN/off Switch on the inverter (2, fig 3.1.1 and
3.2.1) should be in off position. If this switch is left in oN condition and the remote Control is
switched off, using the oN/off button on the remote control, the inverter will not switch off
completely. This will result in draining of the battery due to (i) self consumption of the inverter
and (ii) continuous running of the cooling fan(s) at slow speed.
4.10 USB cHARGInG PoRt
Models SSW-350-12A and SSW-600-12A are provided with USb Charging Port (3, fig 3.1.1).
This port can be used for charging batteries in USb compatible personal devices like cell phones, etc. The
port is rated at 5V, 500mA.
sectIOn 5 |
Operation
5.1 SWItcHInG on AnD SWItcHInG oFF on LoAD
Please ensure that the following procedure is used for switching oN and switching off the inverter
when a load is already connected to the inverter:
Switching on
1. Switch off the load connected to the inverter
2. Switch oN the inverter
3. Wait for a few seconds
4. Switch oN the load
Switching oFF
1. Switch off the load connected to the inverter
2. Switch off the inverter
5.2 connectInG LoADS
1. Make sure that the single load or the combined load requirement of your equipment does not
exceed the inverter’s output rating.
2. Switch off the inverter
3. Switch off the load
4. Plug the cord(s) from the load(s) into the AC receptacle(s) of the inverter
5. Switch on the inverter. Wait for a few seconds
6. The green LeD indicator will be lighted to indicate that the inverter is functioning
7. Switch on the load(s)
The inverter is engineered to be connected directly to standard electrical and electronic equipment in
the manner described above. Do not connect the power inverter to household or RV Ac distribution
wiring. Do not connect the power inverter to any Ac load circuit in which the neutral conductor is
connected to Ground (earth) or to the negative of the Dc (battery) source.