14
Section 4 |
installation
4.7). for this, cut the cable around 2” from the lug and splice it to the appropriate cable to be used for
permanent installation (Cable sizing as per Table 4.1). Use appropriate butt Splice Connector.
SSW-1000-12A, SSW-1500-12A and SSW-2000-12A
The inverter side of the DC input cable has to be terminated with a ring / Tongue type of terminal lug
to fit M9 or 3/8” size of stud on the DC Input terminal (7, 8 in fig 3.2.2). The terminal lug may be crimped
/ soldered.
4.7 cABLe SetS WItH BAtteRY cLAMPS FoR teMPoRARY InStALLAtIon oF SSW-350-12A
AnD SSW-600-12A
for convenience of portable use of the lower powered Models SSW-350-12A and SSW-600-12A during
temporary, stationary applications, the following 2 sets of 3 ft, 105°C rated battery cables have been
provided (10a in fig 3.1.2):
a)
For SSW-350-12A: AWG# 12 cable with flat rectangular Terminal Lug (10b in fig 3.1.2) for inverter
side and battery Clamps for battery side
b)
For SSW-600-12A: AWG# 8 cable with flat rectangular Terminal Lug (10b in fig 3.1.2) for inverter
side and battery Clamps for battery side.
warnInG!
The above cable sets should be used oNLY for temporary / stationary applications for low power
AC loads like portable audio / cell phone charger / laptop etc as the battery clamps may not
provide a very firm battery connection especially in non-stationary environment. For safe and
permanent application, please use wire sizing and fuses recommended in table 4.1.
4.8 MAKInG Dc SIDe connectIonS
1. ensure that appropriate cable size is used as per columns 7 and 8 of Table 4.1. Cable terminal lugs
should be properly crimped / soldered at the bare ends of the cables for secure connections (Please
refer to Section 4.6 for details).
2. ensure that the bare Positive and Negative terminals of SSW-1000/1500/2000 (fig 3.2.2) are
protected using plastic covers with Thumb Nuts (10 in fig 3.2).
3. ensure that the inverter’s power switch is turned off and that no flammable fumes are present.
4. Identify the Positive (+) and Negative (-) terminals of the 12V battery or the other 12V DC source.
5. Install a fuse holder close to the Positive (+) terminal of the battery (or other DC source), preferably
within 7” of the terminal (see fig 4.2). When Marine rated battery fuse (Mrbf) and associated
fuse block recommended at column 5 of Table 4.1 are used, the fuse will be installed on top of the
battery Positive post/stud.
6. Insert a suitable fuse in the fuse holder. for fuse sizes, please refer to column 4 of Table 4.1.
7. Check to be sure that all connections are secure and tight.
8. Test the inverter by turning it on and plugging in a 100 Watt lamp or equipment.
9. If the inverter does not operate properly, then refer to Section 7, Troubleshooting of this manual.
!
cAUtIon!
Loose connectors may cause overheated wires and melted insulation.