Dimensions
Trouble-shooting
Problem
Possible cause
Remedial Action
LCD: no indication.
Bad battery contact.
Check battery contacts.
Not enough measure-
ment precision.
Wrong K FACTOR.
With reference to paragraph H,
check the K FACTOR.
The meter works below.
minimum acceptable flow rate.
Increase the flow rate until an
acceptable flow rate range has
been achieved.
Reduced or zero flow
rate.
TURBINE blocked.
Clean the TURBINE.
The meter does not
count, but the flow rate
is correct.
Incorrect installation of
gears after cleaning.
Repeat the reassembly pro-
cedure.
Possible electronic card
problems.
Contact your dealer.