44 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 45
SECTION 12 |
Specifications
MODEL NO.
PST-60S-48E
OUTPUT
OUTPUT VOLTAGE
230 VAC ± 3%
MAXIMUM OUTPUT CURRENT
2.7A
OUTPUT FREQUENCY
50/60 Hz ± 1% (Switch selectable ; Default: 50 Hz)
TYPE OF OUTPUT WAVEFORM
Pure Sine Wave
TOTAL HARMONIC DISTORTION OF
OUTPUT WAVEFORM
< 3%
CONTINUOUS OUTPUT POWER
(At Power Factor = 1)
600 Watts
SURGE OUTPUT POWER
1000 Watts (< 10 ms)
PEAK EFFICIENCY
> 90%
AC OUTPUT CONNECTIONS
European "Schuko", CEE 7/3 AC receptacle
INPUT
NOMINAL DC INPUT VOLTAGE
48V
DC INPUT VOLTAGE RANGE
42.0 - 64.0 VDC
MAXIMUM DC INPUT CURRENT
20 ADC
DC INPUT CURRENT AT NO LOAD
0.3A
DC INPUT CONNECTIONS
Tubular hole diameter: 11 mm / 0.433" ; M8 Set Screw
DC INPUT FUSES (INTERNAL)
2 x 10A = 20A (Each 10A, 58 VDC, Blade Type)
DISPLAY
LED
Power, Overload, Over Temperature
PROTECTIONS
LOW DC INPUT VOLTAGE ALARM
42.0 ± 0.5 VDC
LOW DC INPUT VOLTAGE SHUTDOWN
40.0 ± 0.5 VDC ; Auto-reset: 46.0 ± 0.5 VDC
HIGH DC INPUT VOLTAGE SHUTDOWN
64.0 VDC ; Auto-reset: < 64.0 VDC
SHORT CIRCUIT SHUTDOWN
When output voltage drops to 160 VAC or lower for 1 to 1.5 sec
OVERLOAD SHUTDOWN
At overload of 110% to 115% for 2 to 2.5 sec
OVER TEMPERATURE SHUTDOWN
90°C ± 5°C ; Auto reset at 65°C ± 5°C
REVERSE POLARITY ON
DC INPUT SIDE
External / internal DC sides fuses will blow
REMOTE CONTROL
WIRED REMOTE CONTROL
RC-15A with LED display and 5m / 16.5ft cable
(Sold separately)
COOLING
FORCED AIR COOLING
Temperature controlled fan (Temperature sensed at internal
hot spot) Fan ON at 55°C ± 3°C; Fan OFF at 45°C ± 3°C
COMPLIANCE
SAFETY
Meets EN 60950-1 for Information Technology Equipment
EMI / EMC
EN 55022: Class B; EN 55024; EN 61000-3-2; EN 61000-3-3
ENVIRONMENT
WORKING ENVIRONMENT
Indoor use
OPERATING TEMPERATURE RANGE
-20˚C to 40˚C / -4˚F to 104˚F
STORAGE TEMPERATURE
-30 to 70˚C / -22 to 158˚F
RELATIVE HUMIDITY
Up to 85%, non condensing
DIMENSIONS
(W X D X H), MM
240.6 x 281 x 82
(W X D X H), INCHES
9.47 x 11.06 x 3.23
WEIGHT
KG
2.7
LBS
5.9
NOTES:
1. All power ratings are specified for resistive load at Power Factor = 1.
2. All specifications given above are at ambient temperature of 25
°
C / 77
°
F.
3. Specifications are subject to change without notice