42 | SAMLEX AMERICA INC.
SECTION 10 |
Protections
10.6 INTERNAL DC SIDE FUSES
The following DC side fuses have been provided for internal protection of the DC input
side. The fuses are 58V, Blade Fuses.
PST-60S-48E: 2 pieces of 10A in parallel = 20A total
10.7 REVERSE POLARITY AT THE DC INPUT TERMINALS
The Positive of the battery should be connected to the Positive DC input terminal of
the inverter and the Negative of the battery should be connected to the Negative DC
input terminal of the inverter. A reversal of polarity (the Positive of the battery wrongly
connected to the Negative DC input terminal of the inverter and the Negative of the
battery wrongly connected to the Positive DC input terminal of the inverter) will blow
the external / internal DC side fuses. If the DC side fuse is blown, the inverter will be
dead. The Green LED marked "POWER" (2, Fig 6.1) will be switched OFF and there will
be no AC output.
i
INFO
Reverse polarity connection is likely to damage the DC input circuitry. The internal fuse(s)
should be replaced with the same size of fuse(s) used in the unit. If the unit does not work
after replacing the fuse(s), it has been permanently damaged and will require repair /
replacement (Please read Section 11 - “Troubleshooting Guide” for more details).
!
CAUTION!
Damage caused by reverse polarity is not covered by warranty! When making battery
connections on the input side, make sure that the polarity of battery connections is correct
(Connect the Positive of the battery to the Positive terminal of the unit and the Negative of
the battery to the Negative terminal of the unit). If the input is connected in reverse
polarity, DC fuse(s) inside the inverter / external fuse will blow and may also cause
permanent damage to the inverter.