28 | SAMLEX AMERICA INC.
And finally, the actual desired rated capacity of the batteries is determined based on
the fact that normally only 80% of the capacity will be available with respect to the
rated capacity due to non availability of ideal and optimum operating and charging
conditions. So the final requirements will be equal to:
125 Ah ÷ 0.8 = 156.25 Ah (note that the actual energy required by the load was 300 Ah).
It will be seen from the above that the final rated capacity of the batteries is almost
2 times the energy required by the load in Ah. Thus, as a Rule of Thumb, the Ah
capacity of the batteries should be twice the energy required by the load in Ah.
7.17 CHARGING BATTERIES
Batteries can be charged by using good quality AC powered battery charger or from
alternative energy sources like solar panels, wind or hydro systems. Make sure an ap-
propriate Battery Charge Controller is used. It is recommended that batteries may be
charged at 10% to 13% of their Ah capacity (Ah capacity based on C-Rate of 20 Hr
Discharge Time). Also, for complete charging (return of 100% capacity) of Sealed Lead
Acid Battery, it is recommended that a 3 Stage Charger may be used (Constant Current
Bulk Charging Stage
}
Constant Voltage Boost / Absorption Charging
}
Constant Voltage
Float Charging).
In case, Wet Cell / Flooded Batteries are being used, a 4-stage charger is recommended
(Constant Current Bulk Charging Stage
}
Constant Voltage Boost / Absorption Stage
}
Constant Voltage Equalization Stage
}
Constant Voltage Float Stage).
SECTION 8 |
Installation
WARNING!
1. Before commencing installation, please read the safety instructions explained
in Section 1 titled “Safety Instructions”.
2. It is recommended that the installation should be undertaken by a qualified,
licensed / certified electrician.
3. Various recommendations made in this manual on installation will be super-
seded by the National / Local Electrical Codes related to the location of the
unit and the specific application.
8.1 LOCATION OF INSTALLATION
Please ensure that the following requirements are met:
SECTION 7 |
General Information on Lead Acid
Batteries
Содержание PST-60S-48E