Trouble Shootings
13.2.1 12V battery
If the multi-meter displays a voltage of 10V or less, this indicates that the battery is defective
and can not be charged any longer.
13.2.2 24V battery
If the multi-meter indicates a voltage of 20V or below, allow the battery be checked by a
specialist, if necessary dispose of the battery.
13.3 The battery discharges after a short period of time without usage
Measure the voltage at the battery terminals with a suitable multi-meter. If the multi-meter
indicates a voltage below 12V of a 12V battery or a voltage below 24V of a 24V battery, then
the battery is too weak to retain the charge.
13.4 Please refer to the following table for other trouble shootings
Table 13-1 Abnormal Functional Check Table
"E.Q." LED (not in Lithium mode) "STATUS" LED
Status
Red, flashing
Red, constantly lit
Short circuit and low voltage,
shut down
Red, flashing
Orange, constantly lit
Battery temperature abnormal,
stop charging (TF-100)
Red, flashing
Red, flashing
Fan abnormal
Red, flashing
Orange, flashing
TF-100 connected to the remote
socket
Red, flashing
Green, flashing
Charger overheated (>100°C),
stop charging
Red, flashing
Red and green by turns
Charging voltage too high and
shut down
Red, flashing
Orange and green by turns
Charging current too high and
shut down
Red, flashing
Red and orange by turns
Defective fuse or reverse-
polarity
Red, flashing for 10 seconds
Void setting
Содержание WSC-1250Li
Страница 5: ...5 Figure 6 Cable Setup Figure 5 Making Connections...
Страница 6: ...6 Figure 7 Fork Figure 8 Switch...
Страница 7: ...7 Figure 9 Temperature Sensor TF 100 Figure 10 Remote Controller RC 600...
Страница 8: ...8 Figure 11 Remote Controller RC 600 Dimension mm Figure 12 Remote Controller RC 601D...
Страница 9: ...9 Figure 13 Remote Controller RC 601D Dimension mm Figure 14 Making Connections RC 601D...
Страница 10: ...10 Figure 15 Temperature Sensor Setup...
Страница 39: ...www samlex com www samlex solar com...