21
ENG
8
Settings Gel/AGM/Lead-acid
8.2.3 Selection Gel/AGM/loodzuur/Lithium
Table 8-5 Switch Configure GEL/AGM/lead-acid / Lithium
Switch 8
Charge mode
OFF
Gel/AGM/lead-acid
ON
LiFePO4 (Lithium)
8.3 Equalization setting
When the switch S3 “E.Q.” is pushed, the function of equalization is activated and the “E.Q.”
LED will light RED. Whenever the function of equalization is activated, it only can be cancelled
by turning off the charger.
Note
The equalization function can be set only when the charger is NOT in the half power mode and NOT in
the power supply mode. (See Table 8-6 VOID Setting table for pushing switch on front panel, Page. 21).
8.4 VOID setting table
To avoid the void setting, please refer to Table 8-6 VOID Setting table for pushing switch on
front panel, Page. 21.
Table 8-6 VOID Setting table for pushing switch on front panel
Push switch on front
panel
Original working mode
Half power
Equalization
Others
Power Supply
S2 "HALF POWER"
pushed or DIP switch 7
in ON position
Exit "HALF
POWER"
("STATUS" LED
lights)
VOID
Enter "HALF
POWER"
("STATUS" LED
flashing)
VOID
S3 "E.Q." pushed
VOID
VOID
Equalization
("E.Q." LED
lights Red)
VOID
Содержание WSC-1250Li
Страница 5: ...5 Figure 6 Cable Setup Figure 5 Making Connections...
Страница 6: ...6 Figure 7 Fork Figure 8 Switch...
Страница 7: ...7 Figure 9 Temperature Sensor TF 100 Figure 10 Remote Controller RC 600...
Страница 8: ...8 Figure 11 Remote Controller RC 600 Dimension mm Figure 12 Remote Controller RC 601D...
Страница 9: ...9 Figure 13 Remote Controller RC 601D Dimension mm Figure 14 Making Connections RC 601D...
Страница 10: ...10 Figure 15 Temperature Sensor Setup...
Страница 39: ...www samlex com www samlex solar com...