6.3.2. Procedure D2: Replacement of sleeves and porous tubes of the transfer pump
Disassembly of the transfer pump:
• Unscrew the 4 M6 x 100 screws (
C
) to release the 2
inlet and outlet collectors (
B
) from the pump body (A).
• Remove the sleeve (
G
), spacer sleeve (
F
), sleeve
cones (
E
) and seals (
D
) assemblies from the pump
body.
• Remove the sleeve interface sockets (
I
) and seals (
H
)
from the pump body (
A
).
• Remove the porous tubes (
J
) from the pump body (
A
).
• Replace damaged components.
• Proceed in reverse order for reassembly.
After reassembly, it is imperative to check the continuity of the grounding on each of the
ringed sockets via the general grounding.