WARNING
During operation, make sure that the pump is always
completely filled with liquid. The permanent pumping of
ignitable gas/liquid mixtures leading to a zone 0 inside
the pump is prohibited.
The pump medium can exothermically react with the
material of the pump. Before pumping the medium, check
the suitability of the pump materials for the medium to be
pumped.
Operation of the pump above the permissible flow rate and
longer dry operation can cause overheating of the pump.
When pumping media in ring systems, the conveying
capacity of the pump is converted into heat. In case of
short lines, this can lead to dangerous heating of the
medium.
Operation of the pump can adiabatically compress
potentially explosive gas mixtures in the pump and/or the
piping system. This can lead to explosive increases in
temperature. The operator has to take appropriate
measures. The media outlet must not be closed during
operation of the pump.
The special operating conditions of the pump must be kept
in mind and adhered to.
WARNING
Destruction of the pump from too high air pressure!
Too high an air pressure can lead to the diaphragm
being destroyed and the pump bursting.
Operate the pump with a maximum air pressure of 8 bar
/ 116 psi.
Make sure that the outlet point of the medium to be
conveyed is not clogged or closed.