Routing Communication Cable
Communication cable must be kept a minimum of one (1) foot away from AC wiring or
fluorescent lighting and at least five (5) feet away from large transformers or motors. If
the communication cable must cross AC wiring, it must cross at a 90
°
angle to the AC
wiring.
Metal Conduit should be used wherever there is a chance of damage to the wire including
telephone rooms and basements (where rodents could pose a problem). This conduit
should be attached to the building ground not the isolated ground.
Communications cable must NOT be placed alongside or in the same conduit as AC power
or telephone signals.
The bending radius on CAT 5e UTP or STP cable is to be a minimum of 1 inch.
Plenum Ceilings
The Plenum rated Category 5 cable, has a durable Teflon coating and is safety rated for air
plenums. Conduit is only needed when the communication cable is exposed in areas of high
traffic or harsh conditions (exterior mounted cables, Terminal and Printer locations in kitchen
and bar areas etc.).
Direct Burial Cable
For exterior use, Category 5 direct burial cable is specially designed for direct burial with a
durable covering for protection.