Setting up:
Customer service
instructions
Do not allow magnetic data carriers such as diskettes, credit cards,
cheque cards, ID cards with magnetic strips, magnetic tapes or watches
to come within 0.5 m of the unit.
Warning: magnetic field Customer service staff with active physical aids (such as heart pacema
kers) must observe a safety distance of at least 0.5 m from the unit.
The customer service operator must ensure that all other people with
active physical aids (such as heart pacemakers) observe a safety distance
of at least 0.5 m from the unit.
Rehinging the door
The door can be easily rehinged within 10 to 15 minutes. Because the
unit casing has to be opened for this purpose, current-carrying parts will
be exposed. The door may only be rehinged by specialist personnel (qua-
lified electrician, service fitter, Hugentobler AG authorised sales person),
and only in accordance with the customer service instruction provided for
this purpose.
Withdraw the mains plug from the socket. Withdraw the plug from the equipment socket of the unit controller. Sto-
re the power cable where it is inaccessible to other persons for the duration of the customer service work. Remove
the two lower hinge screws and unhinge the door. Remove the screw on the opposite side which holds the casing in
place at the bottom front. At the rear of the unit, remove the six screws attaching the housing to the rear wall.
Slide the casing towards the rear and at the front of the unit press the main insulation slightly backwards in order
to gain access to the two earth plates on which the four magnets are located. Dismantle the two earth plates and fit
them on the opposite side. Slide the main insulation forwards again and slide the casing into the front panel.
Securely tighten all six screws on the rear panel. Securely tighten the screw which holds the casing in position at the
bottom front. Unscrew the upper hinge pins and fit them on the opposite side. On the side of the door on which the
door hinge sleeves are fitted, remove the cover caps located on the inside of the door. Remove the cover caps on
the narrow side of the door. Lever the door hinge sleeves out of the holes using a suitable slotted screwdriver and fit
them on the opposite side. Refit the cover caps on the narrow side and the inside of the door. The door must not be
fitted upside down, as in this case the dehumidification vent would no longer be in the optimum position. Therefo-
re, the door handle must also be repositioned. To do this, dismantle the door handle and fit it on the opposite side.
Rehinge the door on the upper door hinge pin and secure it by firmly tightening the lower door hinge.
Power connection
Connect the power cable to a socket with a 230V/ 50/60Hz supply.
Cleaning
Before using for the first time, it is imperative that the white protective
film be removed. In addition, we recommend that the unit be dusted insi-
de and out, with a damp cloth.
�
!
Package contents:
The package contains: 1 unit, 2 side rails, 1 set of operating instructions,
2 power cables (1 x EU/1 x CH). Check the package contents. If parts are
missing, return immediately to your supplier.
The product has been supplied to you in cardboard packaging. Dispose
of the packaging properly or return it to your supplier.
Damage in transit
Check the unit for visible signs of damage.
Do not use the unit if defective. Report the damage immediately to your
supplier.
Placement requirements:
The Hold-o-mat can be used in many different parts of the kitchen, pre-
ferably in a central location, not in a remote corner. Thanks to its ease of
installation (no water, drainage or air extraction connections), the unit
can be placed anywhere. Ensure, however, that the power supply is 230V/
50/60Hz. If the Hold-o-mat is built-in, sufficient cool air should be
allowed to circulate.
The Hold-o-mat does not have to be tied to one location. It can be used
in a variety of places such as the kitchen, lounge, and for parties etc.
If the unit is permanently installed in one place and cannot be disconn-
ected from the mains by a switch, the plug on the power cable must
remain accessible.
�
!
– Place the unit on sturdy surface.
– Ambient tempe 10°C to + 40°C. Do not place the unit next to
or on top of hot surfaces (radiators or hot plates):
there is a danger of
melting, fire or short circuit!
– Never bring the unit into contact with water or other liquids as there is
a
danger of short-circuit!
– To ensure adequate air circulation, all sides of the unit must be kept a