Operating Instructions
85 / 92
13.7.3 Cleaning the cooking chamber behind the air baffle.
.
Switch the appliance off.
.
Switch off the mains switch and secure it against being switched back on.
D
The air baffle may not be dismantled or mounted while the ventilator is still running!
D
The device may not be operated without air baffle!
Removal of the air baffle
Typ 623T, 611T, 1011T
.
Unlock the two locks with a screwdriver by tur
ning them to the right.
.
Unhook the air baffle from the lower guide pins
and remove it.
.
Remove any possibly remaining soiling behind
the air baffle or on the removable racks with
cleaning agent and a cleaning brush.
Removal of the air baffle
Type 611, 621QT, 1011, 1021QT
.
Lift the air baffle and unhook it from the guide
pins; do not cock (risk of bending the guide pins).
.
Lower the air baffle and remove.
.
Remove any possibly remaining soiling behind
the air baffle or on the removable racks with
cleaning agent and a cleaning brush.
Inserting the air baffles
Inserting the air baffles and grease filter, see page 13
section 5.1.3
Air baffle (at rear of cooking chamber)
Guide pin
Locking
Open
Closed
Air baffle (at left in cooking chamber)
Guide pin
Seat for guide pin, top