GUSHER HEAD
VALVE
7
RECIRCULATION
VALVE
6
3
SALVAGE
BASIN
2
RESERVOIR
SCREENS
4
SAFETY
COVER
DRAIN
VALVE
5
A
CONTROL PANEL
D
C
B
1
IMPORTANT!
Do NOT use corrosive chemicals for scrapping or cleaning purposes!
Operating Instructions
TO START:
l
1
Close DRAIN VALVE.
l
2
Position RESERVOIR SCREENS in bottom of tank.
l
3
Lower SALVAGE BASIN over reservoir screens.
l
4
Lower SAFETY COVER over disposer.
l
5
Press START button on CONTROL PANEL. Allow
time for reservoir tank to fill and maintain a constant
flow of water down the trough.
l
6
Adjust THE RECIRCULATION VALVE
to regulate the flow of water.
l
7
If gusher heads are being used along the trough,
adjust the GUSHER HEAD VALVES individually
to the desired settings.
TO STOP:
l
A
Press STOP button on the
CONTROL PANEL.
l
B
Open DRAIN VALVE.
l
C
Allow time for trough to drain.
Raise SALVAGE BASIN.
l
D
Remove RESERVOIR
SCREENS from tank.
Do not dump waste in tank!
Rinse SALVAGE BASIN,
SCREENS, tank interior and
separator discs thoroughly.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Machine will not turn on.
Tank will not fill up.
Only hot or cold water is
going into tank.
Pump motor not running.
Water leaks from pump.
Water flow down trough is
very slow.
Food is not moving over the
separator into the disposer.
Gearmotor is not turning.
Gearmotor is running backwards.
Pump seal/o-ring worn.
Clamps loose.
Door open over disposer.
Overload tripped.
Proximity switch inoperative.
Pump motor inoperative.
Clogged pump.
Pump motor running backwards.
Impeller broken.
Separator not working properly.
Remove debris from pump.
Reverse rotation of pump.
Replace impeller.
Verify separator is running properly. Verify cleaners are
installed properly. Clean if needed.
Hot or cold valve closed.
Blender is out of adjustment.
Drain open.
Door open over disposer.
Line disconnect turned to off position.
Door open over disposer.
Proximity switch inoperative.
Check gearmotor and replace if bad.
Reverse rotation of motor.
Replace seal/o-ring.
Tighten clamps.
Close door.
Wait for overload to cool and check for cause of reset to
trip, i.e. debris in pump.
Replace switch.
Replace pump motor.
Open valves.
Adjust setting of blender.
Close slip valve.
Close door.
Turn disconnect on.
Close door.
Replace switch.
HydroLogic Control Operation:
1. Press the START button to begin operation. (* If the Line Disconnect is in the
OFF position it will need to be turned to the ON position.)
• Display will read “TANK FILL DELAY” for 30 seconds.
• The pump then starts and display reads “SYSTEM ON”.
2. To utilize the Energy & Water Saver feature, press the ON/OFF button. The blue light
above the button will illuminate to indicate the feature is turned on.
3. When in Energy & Water Saver mode, the machine will stop after the run time reaches zero.
4. To increase or decrease the run time, use the + and - buttons to adjust to the desired
run time.
5. Press the STOP button to end operation.
Troubleshooting
WARNING! DISCONNECT THE POWER TO THE SYSTEM BEFORE SERVICING.
This troubleshooting guide is to provide basic checks to facilitate problem isolation and repair. All repairs should be made according to local codes and by a qualified technician.
5