Electrical
Plumbing
3
/
4
" VALVE (NF)
1
1
/
2
"
VALVE (NF)
1
1
/
2
"
PIPING (NF)
3
/
4
" PIPING (NF)
45
O
GUSHER HEAD (OPTIONAL)
1
5
/
16
" HOLE REQUIRED
2" RESERVOIR
DRAIN
3" DISPOSER
DRAIN
DIFFUSER
2" HOLE
REQUIRED
Plumb 1
1
/
2
” pipe from the 1
1
/
2
” rubber coupler supplied on the end of the TroughVeyor unit
to the far end of the fabricated trough and attach it to the water diffuser (Refer to the Diffuser
Installation Detail in the Fabricator Instructions on page 2). A 1
1
/
2
” valve must be installed
as close to the end of the fabricated trough as possible to regulate pump flow capacity. If
optional gusher heads are to be mounted along the fabricated trough for scrapping and pre-
flushing, they should be connected to the main 1
1
/
2
” recirculation line reducing to 3/4” with a
3/4” valve in each gusher head line to regulate the flow. Allow 3’ between gusher heads to
accomodate one operator per gusher head. Configure gusher head plumbing as shown to
reduce splash when starting TroughVeyor.
AIR GAP
WATER BLENDER
HOT WATER
CONNECTION
COLD WATER
CONNECTION
COLD WATER
CONNECTION
HOT WATER
CONNECTION
WATER SUPPLY
The Salvajor TroughVeyor is designed for easy plumbing installation. The
solenoid valves are factory installed and are attached to an automatic water
blender which will introduce water tempered to approximately 107˚ F. Plumb
3/4” lines from both hot and cold water supply sources and reduce to 1/2”
before attaching to corresponding valves on the TroughVeyor water harness.
IMPORTANT:
The TroughVeyor is equipped with an approved air gap,
eliminating the need for vacuum breakers. The Uniform Plumbing Code
states that air gaps are accepted as replacements for vacuum breakers with
foodwaste disposing systems.
NOTE:
To assure against leaks, tighten water harness fittings. They may
come loose during shipment, fabrication or installation. Pressure regulators
should be installed in areas where water pressure exceeds the recom-
mended maximum of 80 psi.
MAKE ALL PLUMBING CONNECTIONS IN ACCORDANCE
WITH NATIONAL AND LOCAL PLUMBING CODES.
DRAIN PIPING
There are two (2) drain connections to be made on the
TroughVeyor system. The TroughVeyor reservoir tank
drain is supplied with a simple quick-opening drain valve
using a 2” rubber coupler to connect to your 2” drain pipe.
3” piping is recommended for the disposer drain. These
two (2) drain lines can be run separately or can be com-
bined per local plumbing codes.
Model
TVL
DRAIN PIPING
OR
OR
Model
TVR
DRAIN PIPING
INCOMING POWER
1
/
2
" CONDUIT KNOCKOUT
DISPOSER CONNECTION
1
/
2
" CONDUIT KNOCKOUT
DISPOSER CONNECTION
1
/
2
" CONDUIT KNOCKOUT
DISPOSER CONDUIT CONNECTION
NOTE:
Always use watertight
conduit and fittings when
wiring this product.
MAKE ALL INSTALLATIONS IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICAL CODES.
ELECTRICAL
The Salvajor TroughVeyor is designed for easy electrical in-
stallation. Components such as the pump motor, solenoids,
separator motor, etc. are all factory pre-wired. The field wiring
on the TroughVeyor consists of two (2) simple steps.
First,
wire from the disposer to the 1/2” knockout provided
for you on the control panel that is located on the front of the
TroughVeyor.
Second,
run power from the power source to the control
panel. A 1/2” knockout is provided on the water harness side
of the control panel.
Complete wiring diagrams will be found inside the Trough-
Veyor control panel. The disposer wiring diagram will be
found attached to the junction box cover located on the bot-
tom of the disposer, as well as in the disposer installation
manual.
IMPORTANT:
The pump must be checked for proper rota-
tion. When facing the front of the pump located on the bottom
of the TroughVeyor, the proper rotation is clockwise.
NOTE:
The TroughVeyor is equipped with a safety lid switch
which is located at the safety cover over the disposer. The
safety lid switch is activated whenever the disposer safety
cover is opened, cutting power to the TroughVeyor system.
ALL 3 PHASE/TOTAL FULL LOAD AMPS
MODEL 208V 230V 460-480V TOTAL HP
300-TV 12.64 11.66 5.83
3.92
500-TV 17.64 16.16 8.13
5.92
LEFT HAND - Model
TVL
RIGHT HAND - Model
TVR
LEFT HAND - Model
TVL
RIGHT HAND - Model
TVR
4