8 .4
Para. #
Function
Default
Range
Description
P19
Radiator Actuator
Control
ON/OFF
ON/OFF
PI
ON/OFF radiator valve control uses simple proportional control
PI radiator valve control is described in detail in the ARV/AVA
Radiator Valve Actuator manual . This parameter is only available if
P01 = RDTR VLV .
P21
Valve Protection
ON
ON (enabled)
OFF (disabled)
When enabled, the radiator valve protection function periodically
operates the valve, exercising it to prevent failure . This parameter is
only available if P01 = RDTR VLV .
P25
Key Lock Source
KYS+APP
APP
When KYS+APP is selected, parameter P26 (Lock Setpoint) can be
activated from either the display and keypad of the AWRT10RF
Thermostat by using the SALUS Smart Home application . If APP
is chosen, parameter P26 is only available online via the mobile
application . This parameter is only available from internet
connected thermostats .
P26
L
ock Setpoint
Unlock
Unlock
Lock
When set to “Lock”, the temperature setpoint cannot be changed
without changing this parameter to “Unlock” .
AWRT10RF Thermostat Settings & Parameters
AWRT10RF Wireless Radiant Thermostat Parameters
(Continued)
Section 8