ENGLISH
5.7 Advanced programming
MAXIMUM CURRENT
AUT. 16.5 A
MAXIMUM CURRENT
MAN. 16.5 A
IT IS USED TO SET THE
OVERLOAD MAXIMUM CURRENT
OF THE MOTOR
RANGE 0.5 ÷ 36.0A (SA687.xx)
CURRENT DELAY
4 s
CURRENT DELAY
4 s
IT IS USED TO SET THE DELAY
OF THE INTERVENTION FOR THE
PROTECTION OF THE CURRENT
RANGE 1 ÷ 8s
AUT.
INDICATES THAT THE MAXIMUM
CURRENT VALUE HAS BEEN SET WITH
THE AUTO-LEARNING
MAN.
INDICATES THAT THE
MAXIMUM CURRENT VALUE
HAS BEEN SET MANUALLY
RANGE 0.5 ÷ 18.0A (SA684.xx)
MINIMUM CURRENT
AUT. 9.9 A
MINIMUM CURRENT
MAN. 9.9 A
RANGE 0.5 ÷ 33.0A (SA687.xx)
RANGE 0.5 ÷ 15.0A (SA684.xx)
IT IS USED TO SET THE
MINIMUM CURRENT
OF THE MOTOR
MAN.
INDICATES THAT THE
MINIMUM CURRENT VALUE
HAS BEEN SET MANUALLY
MINIMUM CURRENT
OFF
AUT.
INDICATES THAT THE MINIMUM
CURRENT VALUE HAS BEEN SET
WITH THE AUTO-LEARNING,
EXCLUDING THE COS
φ
APPLICATION
5.1
5. PROGRAMMING
OFF
EXCLUDES THE CONTROL
ON THE MINIMUM CURRENT
33
OFF
EXCLUDES THE MAX
STARTS CONTROL
IT IS USED TO SET THE MAXIMUM
NUMBER OF STARTS PER HOUR
MAX STARTS PER
HOUR OFF
MAX STARTS PER
HOUR OFF
MAX STARTS PER
HOUR 10
MINIMUM CURRENT
RESET OFF
OFF
EXCLUDES THE
MINIMUM CURRENT RESET
IT IS USED TO SET THE
RESET TIME ON THE
MINIMUM CURRENT
RANGE 1min ÷ 99h 59min
MINIMUM CURRENT
RESET OFF
MINIMUM CURRENT
RESET 0 h 5 m
N.B.:
ABSENT ON
COS APPLICATION
φ
RANGE 1 ÷ 30
MOTOR TEST
OFF
MOTOR TEST
48h
MOTOR TEST
OFF
OFF
EXCLUDES THE
MOTOR TEST
IT IS USED TO SET THE
DELAY BETWEEN EACH
ACTIVATION OF THE MOTOR TEST
RANGE 0FF - 24 - 48 - 72 - 96h