Fig.20 <Sine Output> Secondary Submenu-<Linear & Log>
<Sweep Type>
Setting amplitude sweep type.
<Fixed>
fixed amplitude sweep type(default)
<Linear>
linear amplitude sweep type
<Log>
logarithm amplitude sweep type
In <Fixed> mode, the amplitude of <Sine Output> is set by users. In <Linear> or <Log> mode, settings are
configured in <Sweep Set> and <Sweep Run>.
<Voltage>
Setting the amplitude of sine output
In <Fixed> mode, users can set the amplitude of sine out through keyboard. The range is from 0.001 Vrms to 5
Vrms and the minimum resolution is 0.001Vrms.
<Sweep Set>
Setting the parameters of amplitude sweep.
<Start>
the start amplitude of sweep
<Stop>
the cutoff amplitude of sweep
<Step>
in <Linear> mode, the <Step> is the step amplitude of sweep; in the <Log> mode, the <Step> is the
percentage of amplitude.
<Time>
the step time interval of sweep.
Users can set the start amplitude, cutoff amplitude, step and time through keyboard and soft keys. The range of
amplitude is from 0.001 Vrms to 5 Vrms. The default start amplitude is 1.0 Vrms and cutoff amplitude is 5.000
Vrms. The minimum resolution of amplitude is 0.001 Vrms.
In <Log> mode, the minimum resolution of step is 0.001% and the minimum/maximum resolution of the step time
is 1ms/100,000ms.