Troubleshooting
Fault
Probable cause
Recommended solution
Pump will not
start
Electrical
Check power supply
Check fuse
Check circuit breaker
Inlet/outlet connections
incorrect
Check that connections are plumbed the correct
way round and all valves are open
Insufficient gravity flow Check that installation complies with Salamander
instructions
Check suitability of pump – is installation in
negative head
Check inlet filters are not blocked
Check flow rate min of 2l/min required on both hot
and cold
Float sticking in outlet
Ensure no debris is in outlet area
Flow switch malfunction Contact PumpWise on 0191 5162002
Pump above hot
water cylinder
and becomes
noisy/ low
pressure during
use
Aeration or water
starvation
An Essex Flange with AGL may be required for the
cylinder connection
Ensure pump is a minimum of 600mm below the
cold water tank