15
Helpful
Guidelines -
Water Starvation Protection,
Pipework Arrangements and
Stored Hot Water
Water starvation protection
In systems where it is absolutely not possible
to increase the usable cold water storage
capacity to meet the increased demand of a
pumped system; a water starvation protection
unit (WSP) may be considered.
The WSP is a Salamander level switch which
must be positioned 102mm higher than the
highest outlet from the cold water storage
tank. When the water level drops too far the
WSP will switch off the pump until the cold
water storage level is recovered.
Figure 18: Water starvation protection unit
(WSP)
Shower head size and
Pressure
The size of a shower head dictates the bar
pressure of the pump required to deliver the
expected performance of the shower.
Shower head diameter
Bar pressure
Up to 75mm
1.5 bar (150 kPA)
75 -125mm
2.0 bar (200 kPA)
125 -150+mm
3.0 bar (250 kPA)