9-046
TROUBLESHOOTING
2-5-7. Hydraulic oil filter warning lamp remains ON
Reference Fig.: 2-5-1
Check point
Check/Cause
Action
1. Hydraulic Oil Filter
Switch 1 or 2
when starter switch is OFF, check continuity between
hydraulic oil filter switch 1 or 2 inlet terminal and chassis
ground.
There is no continuity in normal condition.
If there is continuity, hydraulic oil filter switch 1 or 2 is
faulty.
•
•
Replace hydraulic oil
filter switch 1 or 2.
2. Combination Meter
(Hydraulic oil filter
warning indicator lamp)
(1) when starter switch is ON, measure voltage between
combination meter battery terminal inlet wire No. 35
inlet wire YW and ground terminal wire B.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
combination meter hydraulic oil filter warning terminal
outlet wire Y and chassis ground.
There is no electricity in normal condition.
If above items (1) and (2) are OK and no abnormality
is found in hydraulic oil filter switch 1 or 2 but hydraulic
oil filter warning lamp remains on after starting engine,
combination meter is faulty.
•
Replace combination
meter.
3. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance : 10 Ω or less
If resistance is abnormal, harness is faulty.
•
•
Repair or replace
harness.
2-5-8. Engine oil pressure warning lamp remains ON
Reference Fig.: 2-5-1
Check point
Check/Cause
Action
1. Engine Oil Pressure
Switch
Disconnect engine oil pressure switch and check
continuity between its terminals.
There is continuity in normal condition.
If there is continuity, engine oil pressure switch is faulty.
•
•
Replace engine oil
pressure switch.
2. Combination Meter
(Engine oil pressure
warning indicator lamp)
(1) when starter switch is ON, measure voltage between
combination meter battery terminal inlet wire No. 35
inlet wire YW and ground terminal wire B.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
combination meter engine oil pressure warning terminal
outlet wire No. 8 wire YL and chassis ground.
Standard voltage : 12 V or more
If above items (1) and (2) are OK and no abnormality
is found in engine oil pressure switch but engine oil
pressure warning lamp remains on after starting engine,
combination meter is faulty.
•
Replace combination
meter.
3. Harness Connecting
Between Terminals
Measure resistance of harness connecting between
terminals.
Standard resistance : 10 Ω or less
If resistance is abnormal, harness is faulty.
•
•
Repair or replace
harness.
Содержание SV410-2
Страница 1: ...SV410 2 SHOP MANUAL 3498 6404A 0 ...
Страница 2: ......
Страница 4: ......
Страница 13: ...SAFETY ...
Страница 14: ......
Страница 22: ......
Страница 23: ...SPECIFICATIONS ...
Страница 24: ......
Страница 25: ......
Страница 40: ......
Страница 41: ...ENGINE AND CONTROLS ...
Страница 42: ......
Страница 49: ...HYDRAULIC SYSTEMS ...
Страница 50: ......
Страница 51: ......
Страница 54: ......
Страница 56: ......
Страница 58: ......
Страница 60: ......
Страница 62: ......
Страница 63: ......
Страница 74: ......
Страница 76: ......
Страница 78: ......
Страница 80: ......
Страница 86: ......
Страница 88: ......
Страница 89: ...ELECTRICAL SYSTEM ...
Страница 90: ......
Страница 94: ......
Страница 96: ......
Страница 98: ......
Страница 100: ......
Страница 102: ......
Страница 116: ......
Страница 127: ...VIBRATORY DRUM REAR AXLE ...
Страница 128: ......
Страница 136: ......
Страница 138: ......
Страница 154: ......
Страница 156: ......
Страница 162: ......
Страница 163: ...BRAKE ...
Страница 164: ......
Страница 166: ......
Страница 168: ......
Страница 171: ...INSPECTION AND ADJUSTMENT ...
Страница 172: ......
Страница 202: ......
Страница 203: ...TROUBLESHOOTING ...
Страница 204: ......
Страница 215: ......