3.2 MAJOR CHARACTERISTICS
SAJ grid - tie solar inverter has following characteristics which make SAJ
grid - tie solar inverter “High Efficiency, High input voltage with more PV
panels in series.”
• High input voltage with more PV panels in series.
• Two independent MPP trackers for flexible configuration and easy
installation.
• Ultra-high MPP tracking efficiency for full power range.
• Transformerless design.
• Multi communication interfaces,including RS485,Ethernet RJ45,Wi-Fi.
• Multi language display.
• Easy LCD operation with multi-language display.
• DC switch (optional).
• High-grade power components.
• Small size, light weight, easy installation.
Besides, following functions methods are integrated in SAJ grid - tie solar
inverter:
• Internal overvoltage protection
• DC insulation monitoring
• DC side varistor
• Ground fault protection
• Grid monitoring
• Ground fault current monitoring
• Anti-islanding protection
3.3 DATASHEET
8
Input (DC)
Max. DC Power [W]
Max. DC Voltage [V]
MPPT Voltage Range [V]
MPPT Voltage Range[V](Full Load)
DC Nominal Voltage [V]
Start Voltage [V]
Min. DC Voltage [V]
Max. DC Current Input [A]
Number of DC Connection Sets
Number of MPP Trackers
DC Switch
Output (AC)
Rated AC Power [W]
Max. AC Power [W]
Rated AC Current [A]
Max. AC Current [A]
Norminal AC Voltage/Range
Grid Frequency/Range
Power Factor(cos φ)
AC Current Distortion (THD)
Consumption at Night [W]
Consumption at Standby [W]
Efficiency
Max. Efficiency
Euro Efficiency (at 360Vdc)
MPPT Accuracy
Protection
Internal Overvoltage Protection
DC Insulation Monitoring
DC Side Varistors
Direct Current Monitoring
Ground Fault Current Monitoring
Grid Monitoring
AC Short Current Protection
Thermal Protection
Anti-island protection monitoring
Interface
AC Connection
DC Connection
LCD Display
Display Language
Datalogger & Communication
General Data
Isolation
Operating Temperature Range
Cooling Method
Ambient Humidity
Site Altitude above Sea Level
Noise Emission (
A)
IP Protection
Mounting
Dimensions (WxHxD) [mm]
Weight [kg]
Standard Warranty (Year)
Safety Class Compliance
EMC Compliance
dB
Type
Sununo
-
TL1.5K
Sununo
-
TL2K
480
120-384
360
150
100
1
1
Optional
220V, 230V, 240V/180V-280V
50Hz, 60Hz/ ±5Hz
>0.99 [full load]
< 2%
<0.2
6
>99.5%
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
AFD
Terminals
MC4/H4
LCD(16x2 Characters
Backlight) & LED(3 Lights)
Multi Language
2*RS485(Standard)
Wi-Fi/Ethernet(Optional)
Transformerless
-25°C to +60°C [45°C to 60°C with derating ]
Natural Convection
0% to 98% Non-condensing
Up to 2000m
<40
IP65 [Indoor or Outdoor Installation]
Rear Panel
415*313*140
11
5 / 10 / 15 / 20 / 25 [Optional]
As3100
IEC62109-1/-2
,
,
,
EN61000-6-2
,
EN61000-6-3
,
EN61000-3-2
,
EN61000-3-3
1800
164-384
11
1500
1650
6.5
8.5
97.4%
96.5%
2300
190-384
12
2000
2000
8.7
11.0
97.4%
96.7%
Grid Protection Compliance
VDE 0126-1-1/A1
,
VDE 4105
,
G83
,
RD1699
,
C10/11
,
AS4777.3
,
EN50438
,
CGC/CF004