RJ45

 

cable

RJ45

 

cable

 

is

 

the

 

standard

 

cable

 

for

 

Ethernet

 

communication

Users

 

can

 

buy

 

this

 

cable

 

in

 

stores

or

 

can

 

assemble

 

RJ45

 

cable

 

as

 

below

:

Each

 

end

 

of

 

the

 

cable

 

must

 

be

 

connected

 

to

 

RJ45

 

Plug

 

according

 

to

 

Table

 

4

Make

 

sure

 

they

 

are

 

fixed well

Table

 

4

  

RJ45

 

Cable

 

Assembly

 

Order

RJ45

 

plug's

  

Pin

 

NO

One

 

RJ45

 

plug's

Wire

 

color

The other

 

RJ45

 

plug's 

Wire

 

color

White

 & 

Green

White

 & 

Orange

Green

Orange

White

 & 

Green

White

 & 

Orange

Blue

Blue

White

 & 

Blue

Orange

White

 & 

Blue

Green

White

 & 

Brown

Brown

White

 & 

Brown

Brown

1

2

3

4

5

6

7

8

Object

A

C

D

E

LED light – POWER. 

▼/

ESC

▲/

ENT

Yellow light shines when the inverter is energized.

LED light-RUN. Green light flashes when the inverter runs good. 

SAJ  grid-tie  solar  inverter  offers  two  buttons  for  user  to  look  up  running 
information and configure parameters. The two buttons can be reused.  

Description

Name

Operation

▲/ 

ENT

NOTE: 

The back light of LCD screen will go out to save power if there is no 

button operation in one minute. You can activate it by pressing any button.

It indicates the

button, which can move the cursor 

downwards in the menu, or decrease the setting value.

It  indicates  the 

ESC

button,  which  can  return  to 

parent menu or cancel the demand.

It indicates the 

 button, which can move the cursor 

upward in the menu, or increase the setting value.

▼/ 

ESC

It  indicates  the 

ENT

button,  which  can  enter 

submenu or confirm the command.

LCD screen 

for viewing the running data & recorded information,

and setting parameters.

F

7.    LCD Operation

7.1  LCD DISPLAY

Press less than 

one  second

Press more than 

one second

Press less than 

one  second

Press more than 

one second

7.2  Operation  Method

7.2.1 BUTTON FUNCTION

LED light-FAULT. Red light shines when fault occurs in the inverter and 
automatically goes out when the fault is removed.

B

A B C D

E F

Figure 7.1

Description

Содержание SU3KMTLI

Страница 1: ...663 Tel 86 20 6660 8532 Fax 86 20 6660 8589 E mail info sajelec com Web www saj solar com User Manual Note Since Guangzhou Sanjing Electric Co Ltd has a policy of continuous product improvement it res...

Страница 2: ...maintenance troubleshooting and safety notice As long as you follow the instruction of this manual you will get the professional guidance and our wholehearted service Customer orientation is our fore...

Страница 3: ...8 Pollution Degree 5 9 Overvoltage Category This Manual 6 Electrical Connection 6 1 Safety 6 2 Overview of Connection Area 6 3 AC Side Connection 6 4 DC Side Connection 6 5 DC Side Disconnection 6 6...

Страница 4: ...ROUP Solar energy generation systems based on photovoltaic modules nowadays represent the most suitable solution to reduce the energy consumption produced by oil and gas The solar inverter is a key de...

Страница 5: ...must be performed by qualified personnel only in compliance with national and local standards and regulations Any unauthorized actions including modification of product functionality of any form may...

Страница 6: ...sformer This inverter does not use transformer for the isolation function Certified safety The inverter complies with the requirement of the Equipment and Product Safety Act in Europe CE Mark Equipmen...

Страница 7: ...stortion THD Consumption at Night W Consumption at Standby W Efficiency Max Efficiency Euro Efficiency at 360Vdc MPPT Accuracy Protection Internal Overvoltage Protection DC Insulation Monitoring DC Si...

Страница 8: ...Range V MPPT Voltage Range V Full Load DC Nominal Voltage V Start Voltage V Min DC Voltage V Max DC Current Input A Number of DC Connection Sets Number of MPP Trackers DC Switch Output AC Rated AC Pow...

Страница 9: ...Max AC Current A Norminal AC Voltage Range Grid Frequency Range Power Factor cos AC Current Distortion THD Consumption at Night W Consumption at Standby W Efficiency Max Efficiency Euro Efficiency at...

Страница 10: ...The installation site must have good ventilation condition Installing the inverter under strong sunshine is not recommended the excess heating might lead to power reduction Make sure enough ventilati...

Страница 11: ...h 3 Mount the rear panel Wring six screws into the expansion tubes and tightly mount the rear panel on the wall Figure 5 5 4 Carefully attach the inverter to the rear panel according to the position o...

Страница 12: ...e removed please keep them at a distance Lift the lid upwards and remove it 2 There are 2 varistors for and 4 varistors for Sununo TL in the left side Sununo TL1 5K 2K 3KB 4KB 3KA 4KA 5K SU3KMTLI SU4K...

Страница 13: ...POLLUTION DEGREE SAJ grid tie solar inverters comply with the pollution degree 3 5 9 OVERVOLTAGE CATEGORY Overvoltage category III applies to SAJ grid tie solar inverter AC terminals For PV circuits i...

Страница 14: ...g communication module AC output Heat sink Ethernet optional Figure 6 1 A B C D E F Sununo TL3KA 4KA 5K SU3KMTLI SU4KMTLI SU5KMTLI Bottom 6 3 AC SIDE CONNECTION NOTICE The cross section of the AC cabl...

Страница 15: ...B is allowed on the supply side of this product Provided an AC current or pulse current is caused in the external protective earthing conductor an RCD or RCM of Type AC or Type A as alternative can be...

Страница 16: ...tention to the polarity of the terminals to avoid wrong connecting 6 4 DC SIDE CONNECTION The cable length on DC side should not exceed 30 m Figure 6 6 Figure 6 7 To do this the insulated earthing con...

Страница 17: ...g plug to seal the left DC input set to ensure the inverter IP 65 protection If only one string input is used for DC connection NOTICE DANGER to life due to potential fire or electricity shock Never c...

Страница 18: ...d cable into contact barrel and insure all conductor strands are captured in the contact barrel and the conductors are visible in the contact barrel observation hole See below figures 3 Crimp contact...

Страница 19: ...rs For more detail information please refer to SAJ Monitoring Solution through www saj soalr com Note The text lines in the following Figures indicates communication cable 6 6 1Communication through R...

Страница 20: ...6 2 Communication through Ethernet RJ45 When users choose Ethernet communication solution users can access to Inverter real time information through Inverter IP address or through SAJ Logger IP addres...

Страница 21: ...y Order Figure 6 25 RJ45 Plug and Its Pin Number Tools When making a communication cable the professional tools shown in Figure6 26 below are needed Figure 6 26 Tools for making a communicate cable RS...

Страница 22: ...ameters The two buttons can be reused Description Name Operation ENT NOTE The back light of LCD screen will go out to save power if there is no button operation in one minute You can activate it by pr...

Страница 23: ...UP DOWN E Today E Month E Year E Total E Today E Total UP DOWN Enter Enter Error Code 02 Grid Volt Err S Enter 12 08 26 17 52 12 08 07 10 05 Enter Language Date UP DOWN SN Code Product Code Firmware V...

Страница 24: ...operation The inverter in stand by state The inverter stops working A fault occurs during operation A fault occurs repeatedly and has reached a certain times during operation P fault The state of upd...

Страница 25: ...confirm and then it automatically points to next figure When all the figures have been set Are you sure to set it will appear press ENT to confirm it Press ESC or ENT to exit when Set Complete appear...

Страница 26: ...of master control unit slave control unit display board the firmware version will vary when it is updated SN code Product Code Machine Type Grid Compliance Firmware Ver 45 9 TROUBLESHOOTING Clear Ener...

Страница 27: ...User Manual User Manual 48 47...

Страница 28: ...User Manual 49 User Manual 50...

Страница 29: ...User Manual 51 User Manual 52...

Страница 30: ...n Road Guangzhou Science City Guangdong China P R C Zip 510663 http www saj solar com Technical Support Service Tel 86 20 6660 8619 Fax 86 20 6660 8589 E mail service sajelec com International Sales T...

Страница 31: ...de Voltage at the Maximum Power Point Amperage at Maximum Power Point Open Circuit Voltage Short Circuit Current Alternating Current Form of electricity supplied by Utility Company Direct Current Form...

Отзывы: