PDM20 Series
- 25 -
Function
code
Description
Set range Unit
Default
Display
level
Modific
ationlev
el
Notes
P0.28
Current
percentage of
water shortage
protection
detection
0.0
~
100.0
%
40.0
1
○
It is valid only when
P0.25=01.
Percentage of motor
rated current. When
running current is
smaller than this
current, it judges as
water shortage.
P0.29
Water
shortage
protection
detection time
0
~
900.0
s
20.0
○
P0.30
Self-restarting
delay of water
shortage
protection
0
~
9999
min
15
1
○
If it is set to be 0, use
pressure to self-reset
water shortage.
P0.31
Self-sleep rate
1
~
30
3
1
○
Increase this value
when the system can’t
sleep.
P0.32
Inflow
detection
pressure
0.0
~
P0.00
bar
1.0
1
○
After inflow pressure is
larger than detection
pressure time
(P0.33),water shortage
fault is automatically
reset.
P0.33
Inflow
detection time
0.0
~
100.0
s
1.0
1
○
P0.34
Lower limit of
AI
0.0
~
P0.35
V/mA
4.00
○
P0.35
Upper limit of
AI
P0.34
~
20.00
V/mA
20.00
○
P0.36
Acceleration
time
0.1
~
3600
s
5.0
○
P0.37
Deceleration
time
0.1
~
3600
s
3.0
○
Содержание PDM20 series
Страница 1: ...PDM20 Smart Mini Pump Drive User Manual Version Code PDM20 EN 60200256 1612 ...
Страница 12: ...PDM20 Series 11 Example Modify P0 02 from 0 to 1 Remarks 0 1MPa 100kPa 1bar 1kgf cm2 ...
Страница 14: ...PDM20 Series 13 2 3Dimensions Unit mm 136 116 176 158 114 105 124 138 ...
Страница 59: ...PDM20 Series 58 V1 1 Inverter ...