8000m Series
-
21
-
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F0.03
Master
frequency
source X
6: Multi-step speed
terminals
7: Simple PLC
8: PID
9: RS485 Communication
interface
1
●
F0.04
Auxiliary
frequency
source Y
0: AVI terminal
1: ACI terminal
2: Reserved
1
●
F0.05
Range of
auxiliary
frequency
setting source Y
0: Relative to the maxi.
frequency
1: Relative to master
frequency setting source X
0
●
F0.06
Reserved
F0.07
Frequency
setting source
selection
0:X
1: Y
2: X and Y
3: Maximum value of (X,
Y)
0
○
F0.08
Keypad setting
frequency
0.00Hz~ F0.10
0.01Hz 50.00 Hz
○
F0.09
Running
direction
selection
0: Forward
1: Reverse
2: Reverse running
prohibited
0
●
F0.10
Maximum
output
frequency
10.00~600.00Hz
0.01Hz 50.00Hz
●