8000m Series
-
42
-
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
FA.16
The last fault
11: Motor overload (E011)
12: Input Phase Loss
(E012)
13: Output Phase Loss
(E013)
14: Heatsink overheating
(E014)
15: External fault (E015)
16: Communication fault
(E016)
17: Reserved
18: Current sensing circuit
fault (E018)
19: Motor autotuning fault
(E019)
20: Reserved
21: Reserved
22: EEPROM fault (E022)
23: Pre-alarm fault when
overload (E023)
24: PID feedback loss
fault (E024)
25: Running time reached
(E025)
26: Counting meter
reached (FULL)
◎
FA.17
Running
frequency at the
last fault
Hz
◎
FA.18
Output current
at the last fault
A
◎
FA.19
DC bus voltage
at the last fault
V
0.0V
◎
FA.20
Input terminal
status at the last
fault
0
◎
FA.21
Output terminal
status at the last
fault
0
◎
FB Group: Swing Frequency and Counting Meter Parameters
FB.00
Swing frequency
bandwidth
0.0~100.0% (relative to
setting frequency)
0.1%
0.0%
○
FB.01
Skip frequency
bandwidth
0.0~50.0% (relative
to swing frequency
bandwidth)
0.1%
0.0%
○
FB.02
Rising time of
swing frequency
0.1~3600.0s
0.1s
5.0s
○