8000m Series
-
26
-
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F2.12 Reserved
F3 Group: Vector Control Parameters
F3.00
Proportional
gain 1 of speed
loop
0~100
20
○
F3.01
Integral time 1
of speed loop
0.01~10.00s
0.01s
0.50s
○
F3.02
Low frequency
point of switch
0.00Hz~F3.05
0.01Hz
5.00Hz
○
F3.03
Proportional
gain 2 of speed
loop
0~100
1
25
○
F3.04
Integral time 2
of speed loop
0.01~10.00s
0.01s
1.00s
○
F3.05
High frequency
point of switch
F3.02~F0.10
1Hz
10.00Hz
○
F3.06
Coefficient
of slip
compensation at
VC control mode
50~200%
1%
100%
○
F3.07
Upper limit
torque
0.0~200.0% (inverter
rated current)
0.1%
150.0%
○
F3.08
Reserved
F3.09
Reserved
F3.10
Pre-alarm option
when overload
0: Not detect
1: Effective during running
and keep running after
alarm
2: Effective during running
and stop after alarm (fault
code:E023)
1
○