background image

VISION-LITE® / VISION-LITE II®

PROCESSING GUIDELINES

MAY 2022

5

1. General

VISION-LITE® is a coated glass with very low reflectance (1%). According to the product reference, it is 
available in annealed monolithic with coating on one or two sides or laminated with coatings on both 
sides (see below). VISION-LITE® is produced on DIAMANT® base glass for architectural applications.
The two exterior sides of the glass have a transparent coating of oxides or a coating of metallic nitrides 
which, by reducing the reflectance of the glass surface, enhance the glass transparency and visibility of 
objects seen through it.
As compared to the standard glass, VISION-LITE® has:
• 

Higher transparency

• 

Extremely low light reflectance

• 

High light transmittance

• 

Very high colour contrast

VISION-LITE® II is the to-be-tempered version, it can be toughened, heat-strengthened or curved.
The VISION-LITE® range includes the following types of products:
• 

SEMI VISION-LITE®

 monolithic glass - with coating on one side of the glass only, intended for 

lamination.

• 

STADIP VISION-LITE®

 laminated glass - with two SEMI VISION-LITE® sheets assembled by means of 

one or several PVB layers. The sheets are assembled so that the coating is on the exterior, therefore 
the laminate has coatings on both sides.

• 

VISION-LITE®

 II monolithic glass - with coating on both sides of the glass, meant to be tempered

• 

SEMI VISION-LITE®

 II monolithic glass - with coating on one side of the glass only, intended for 

tempering then lamination.

VISION-LITE® & VISION-LITE® II can be used in single or double glazing unit.
VISION-LITE® is mainly used in retail shops and museums as display case glazing, and in exteriors as 
shop windows or balustrades. VISION-LITE® can also be used for other specific external applications like 
lobby / ground floor glazing and roof-top restaurants. VISION-LITE® is however not recommended for 
façade projects, including multi-storey shop windows.
VISION-LITE® II is recommended for specific applications requiring tempered glass, it can be used as 
external glazing on limited surface. Building applications of VISION-LITE II® must be assessed depending 
on the project. VISION-LITE® II is not recommended for high rise front façade (curtain wall). Contact 
your sales representative for more information.
VISION-LITE® & VISION-LITE® II cannot be mixed on the same glazing surface.
VISION-LITE® range meets the requirements of Class A products as defined in the European standards 
EN1096-1 and EN1096-2. The efficiency of the anti-reflective effect will be maximum in the simple glazing.
For complete performance data, please refer to the Glass Guide, our commercial documentations and 
our website www.saint-gobain-glass.com.
To improve customer satisfaction, we constantly improve the quality of our coatings. This could lead to 
improvement in the processability of our coating, so please make sure you have an up-todate version 
of these guidelines.

1.1. PRODUCT DESCRIPTION

VISION-LITE® range products are usually available in standard thicknesses and sizes. For more details, please 
refer to the relevant product documentation from Saint-Gobain Glass or contact your local sales service.

1.2.1. Thickness and dimensions 

1.2. THICKNESS, DIMENSIONS AND TOLERANCES

Содержание VISION-LITE

Страница 1: ...VISION LITE VISION LITE II PROCESSING GUIDELINES MAY 2022 1 PROCESSING GUIDELINES VISION LITE VISION LITE II...

Страница 2: ...VISION LITE VISION LITE II PROCESSING GUIDELINES MAY 2022 2 DOCUMENT CODE DATE SGG QD C GUI 0013 B 05 2022...

Страница 3: ...he coating 7 1 5 2 Identification of the coated face 9 2 Transport acceptance storage and handling 9 2 1 Transport 9 2 2 Receipt of the delivery 10 2 3 Storage 11 2 3 1 General 11 2 3 2 Shelf life 11...

Страница 4: ...of Insulating Glass Units 17 3 13 Processing quality checks 18 4 Environment waste glass health issues 19 5 Glazing instructions 19 6 Protection cleaning and maintenance of the end products 20 6 1 Pr...

Страница 5: ...can be used in single or double glazing unit VISION LITE is mainly used in retail shops and museums as display case glazing and in exteriors as shop windows or balustrades VISION LITE can also be use...

Страница 6: ...from this norm Uniformity defect slight visible variation in colour in reflection or in transmission within a coated glass pane or from pane to pane Stain defect in the coating larger than punctual de...

Страница 7: ...effect it must be also present on face 2 of the pane This coated glass can be laminated taking care to always place the coating outside of the laminate Use of the coating against the PVB is not allow...

Страница 8: ...panel can be replaced with a low emissivity coated glass like PLANITHERM XN or ECLAZ for instance The association of Semi VISION LITE with other low emissivity coatings must be assessed case by case p...

Страница 9: ...ransported in 2 8 tonnes packs jumbo or split sizes Glass sheets must be transported vertically The individual sheets are packed with the coated side towards the inside of the frame unless otherwise r...

Страница 10: ...ed on the identification label All deliveries are identified with a label providing the following data 2 2 RECEIPT OF THE DELIVERY No claim can be accepted for damages caused during and after processi...

Страница 11: ...ns with vacuum cups on the coated side cannot be avoided make sure that the vacuum cups are perfectly clean Not all solutions are suitable for cleaning vacuum cups see manufacturer documentation for d...

Страница 12: ...other ordinary coated glass However the following recommendations have to be respected Any irregularity or damage of the edges must be avoided since it is likely to increase the risk of breakage durin...

Страница 13: ...h 3210 6000 mm PLF the usable surface is 3170 5960 mm VISION LITE range does not need to be edge deleted whatever the configuration of use It could be used with polysulphide polyurethane or silicone I...

Страница 14: ...and 8 Brushes Flexible soft clean polyamide bristles Maximum diameter of 0 2 mm 20 40 mm long Make care that all the brushes are perfectly clean and regularly maintained Any hard brushes must be lift...

Страница 15: ...utions left on the coating may induce at tempering hot corrosion giving the aspect of pinholes of the coating Such marks may not be washable Also even in case of annealed version there is a risk that...

Страница 16: ...lass presence this must be in certain situations used manually in fact the very low reflectance of the VISION LITE II glass may not be detected by the sensor and therefore it may not send the informat...

Страница 17: ...LITE II is assembled into double glazed units this should be performed within 2 days SEMI VISION LITE for annealed laminated glass or tempered SEMI VISION LITE II only can be laminated with the coatin...

Страница 18: ...etc Visual detection of roller wave Normal control of the toughening quality break pattern etc After heat soak testing Visual aspect control scratches oxidation corrosion splinters etc Check that no d...

Страница 19: ...paint plaster mortar it is recommended that glazings are installed after all other work on site has been completed In case this cannot be respected efficient protection of the glazing by means of poly...

Страница 20: ...cleaning the coating are isopropanol IPA or ethanol Cleaning with the help of solvents must be immediately followed by normal washing with water and rinsing The owner of the building must ensure the...

Страница 21: ...ITE VISION LITE II PROCESSING GUIDELINES MAY 2022 21 SAINT GOBAIN INNOVATIVE MATERIALS POLSKA SP Z O O ODDZIA GLASS ul Szklanych Dom w 1 42 530 D browa G rnicza www saint gobain glass pl bgp saint gob...

Отзывы: