Alkaline products may be emitted from concrete, plaster, mortar... Such materials or materials containing 
fluorine and acids will lead to a staining or matting of the surface. To prevent such an occurrence, all 
such substances must be removed from the glass immediately. It is recommended that the glazing is 
cleaned as soon as it is installed.
Cleaning means: washing, rinsing and drying the glass. A mild soap or neutral detergent can be used, 
and subsequently and immediately rinsing with clear water. Excess water must be removed quickly. 
Washing tools and towels must be free of abrasive particles. Never use abrasive cleaning products or 
compounds likely to generate fluorine salts or hydrofluoric acid. Use of plastic squeegee is possible, just 
be sure to not have abrasive parts blocked in it.
Grease, oil and materials used for facilitating the installation must be removed. The materials 
recommended for cleaning the coating are isopropanol (IPA) or ethanol. Cleaning with the help of 
solvents must be immediately followed by normal washing with water and rinsing.
The owner of the building must ensure the regular and proper maintenance of the glass. This entails 
washing the windows, checking and if necessary repairing joints and frames, checking and, if necessary, 
unclogging the drain and ventilation holes and detecting any anomaly.

6.3. CLEANING AND MAINTENANCE

the coating. If warning signs must be placed, we suggest fixing a notice or streamer to the frame, 
making sure they do not touch the glass.

• 

Paint or strong stickers like used for promotional events must not be applied on VISIONLITE® range. 
Above recommendations have to be considered.

7. Disclaimer

SAINT-GOBAIN GLASS has taken every reasonable measure to ensure that the information contained in 
the present leaflet was exact at the time of its publication.
However, SAINT-GOBAIN GLASS keeps the right to modify or add any information without previous 
notice. SAINT-GOBAIN GLASS is not liable for the possible lack of information on VISION-LITE® (II) 
products that would not be contained in the present document.

Содержание VISION-LITE

Страница 1: ...VISION LITE VISION LITE II PROCESSING GUIDELINES MAY 2022 1 PROCESSING GUIDELINES VISION LITE VISION LITE II...

Страница 2: ...VISION LITE VISION LITE II PROCESSING GUIDELINES MAY 2022 2 DOCUMENT CODE DATE SGG QD C GUI 0013 B 05 2022...

Страница 3: ...he coating 7 1 5 2 Identification of the coated face 9 2 Transport acceptance storage and handling 9 2 1 Transport 9 2 2 Receipt of the delivery 10 2 3 Storage 11 2 3 1 General 11 2 3 2 Shelf life 11...

Страница 4: ...of Insulating Glass Units 17 3 13 Processing quality checks 18 4 Environment waste glass health issues 19 5 Glazing instructions 19 6 Protection cleaning and maintenance of the end products 20 6 1 Pr...

Страница 5: ...can be used in single or double glazing unit VISION LITE is mainly used in retail shops and museums as display case glazing and in exteriors as shop windows or balustrades VISION LITE can also be use...

Страница 6: ...from this norm Uniformity defect slight visible variation in colour in reflection or in transmission within a coated glass pane or from pane to pane Stain defect in the coating larger than punctual de...

Страница 7: ...effect it must be also present on face 2 of the pane This coated glass can be laminated taking care to always place the coating outside of the laminate Use of the coating against the PVB is not allow...

Страница 8: ...panel can be replaced with a low emissivity coated glass like PLANITHERM XN or ECLAZ for instance The association of Semi VISION LITE with other low emissivity coatings must be assessed case by case p...

Страница 9: ...ransported in 2 8 tonnes packs jumbo or split sizes Glass sheets must be transported vertically The individual sheets are packed with the coated side towards the inside of the frame unless otherwise r...

Страница 10: ...ed on the identification label All deliveries are identified with a label providing the following data 2 2 RECEIPT OF THE DELIVERY No claim can be accepted for damages caused during and after processi...

Страница 11: ...ns with vacuum cups on the coated side cannot be avoided make sure that the vacuum cups are perfectly clean Not all solutions are suitable for cleaning vacuum cups see manufacturer documentation for d...

Страница 12: ...other ordinary coated glass However the following recommendations have to be respected Any irregularity or damage of the edges must be avoided since it is likely to increase the risk of breakage durin...

Страница 13: ...h 3210 6000 mm PLF the usable surface is 3170 5960 mm VISION LITE range does not need to be edge deleted whatever the configuration of use It could be used with polysulphide polyurethane or silicone I...

Страница 14: ...and 8 Brushes Flexible soft clean polyamide bristles Maximum diameter of 0 2 mm 20 40 mm long Make care that all the brushes are perfectly clean and regularly maintained Any hard brushes must be lift...

Страница 15: ...utions left on the coating may induce at tempering hot corrosion giving the aspect of pinholes of the coating Such marks may not be washable Also even in case of annealed version there is a risk that...

Страница 16: ...lass presence this must be in certain situations used manually in fact the very low reflectance of the VISION LITE II glass may not be detected by the sensor and therefore it may not send the informat...

Страница 17: ...LITE II is assembled into double glazed units this should be performed within 2 days SEMI VISION LITE for annealed laminated glass or tempered SEMI VISION LITE II only can be laminated with the coatin...

Страница 18: ...etc Visual detection of roller wave Normal control of the toughening quality break pattern etc After heat soak testing Visual aspect control scratches oxidation corrosion splinters etc Check that no d...

Страница 19: ...paint plaster mortar it is recommended that glazings are installed after all other work on site has been completed In case this cannot be respected efficient protection of the glazing by means of poly...

Страница 20: ...cleaning the coating are isopropanol IPA or ethanol Cleaning with the help of solvents must be immediately followed by normal washing with water and rinsing The owner of the building must ensure the...

Страница 21: ...ITE VISION LITE II PROCESSING GUIDELINES MAY 2022 21 SAINT GOBAIN INNOVATIVE MATERIALS POLSKA SP Z O O ODDZIA GLASS ul Szklanych Dom w 1 42 530 D browa G rnicza www saint gobain glass pl bgp saint gob...

Отзывы: