9.0 Air Supply Connection

The BarbLock® Assembly Tool is powered by compressed air that enters the tool through a 1/4” female NPT fitting 
behind the handle. The air supply is to be clean and dry, without lubrication, in order to prevent contamination of 
the BarbLock® products being assembled by the Tool. The maximum allowable and optimal supply pressure is
100 psi (0.7 MPa). Exceeding the air pressure limit can damage components inside the tool. Damage to internal 
components could lead to unpredictable operation, such as “drift” of the jaws toward the closed position. If this is 
observed, then immediately discontinue use of the tool, remove it from the work area and contact Saint-Gobain
Performance Plastics Customer Service. Reduced air pressure may be used for smaller sizes of BarbLocks®, as long 
as full closure of the BarbLocks® is consistently achieved. Pressure should be adjusted as needed to achieve full 
closure of the BarbLocks® in use at the time. 

The User/Owner of this tool is to select their own appropriate air fitting to adapt the tool to their air supply system. 
Torque input to the 1/4” NPT fitting is not allowed at any time. Torque applied to any item being connected to the 
tool must be reacted (backed up) by a wrench placed on the 11/16” external hex of the 1/4” NPT fitting. Failure to
properly react this torque can damage the plastic casing of the tool and possibly other internal components. This 
warning applies to installation and to removal of any item that is attached to the tool’s 1/4” NPT air input fitting.

Minimum recommended inside diameter for the air hose is 3/8” (9.5mm). Smaller hose sizes may not perform well 
with some of the larger BarbLocks® due to restriction of the air supply.

Figure 18: BarbLock® Assembly Tool

Compressed Air Connection 

(Installed)

Tool Balance 

Connection

Jaw set with 

upper and

lower pieces

Содержание BarbLock BLT-HHPAD

Страница 1: ...Saint Gobain BarbLock Assembly Tool Part Number BLT HHPAD OPERATIONS MANUAL www biopharm saint gobain com...

Страница 2: ...Assembly Tool 9 Air Supply Connection 11 Operational and Safety Checks 12 Noise Emissions 12 Vibration 12 Tool Balance Connection and Use 12 Residual Risks 13 Use and Storage Conditions 13 Cleaning 1...

Страница 3: ...sole risk Proper use also includes compliance with operating inspection and maintenance conditions prescribed by the manufacturer Non com pliance with the warnings in the operating instructions and i...

Страница 4: ...nnec tion This creates an ultra secure connection that is more resistant to leakage than any other available technology Figure 2 below shows some of the Saint Gobain products with which the BarbLock A...

Страница 5: ...Saint Gobain brand name and symbol Figure 3 2 Product identification and company information Figure 4 3 This User Operator manual contains critical information that must be understood by the user in o...

Страница 6: ...rved the tool should be disconnected from the air supply and removed from the work area When the jaws are in the closed position a pinch risk is present in gaps just below the lower jaw see Figure 11...

Страница 7: ...will move any time the Safety Cover is closed and the trigger is pressed Keep fingers away from all openings in the area of the jaws Failure to do so could result in a serious pinching injury to the f...

Страница 8: ...not present in this image Jaw tail Figure 14 Example of Upper Jaw showing part number with suffix letter A to indicate upper position Jaws are installed in their respective carriers A suffix on the J...

Страница 9: ...ed to the tool This will happen no matter if the Safety Cover is closed or not Be aware of the possibility that the lower jaw carrier may move while connecting the tool to the pressurized air supply K...

Страница 10: ...o need for the operator to provide intervention to the BarbLock assembly WARNING Pinch Hazard after the BarbLock has fully closed the operator can release the Trigger This will cause the jaws to retra...

Страница 11: ...smaller sizes of BarbLocks as long as full closure of the BarbLocks is consistently achieved Pressure should be adjusted as needed to achieve full closure of the BarbLocks in use at the time The User...

Страница 12: ...nting motion of the jaws any time the Safety Cover is open If the Safety Cover interlock switch is defeated then the jaws can move while the Safety Cover is open and a pinch injury becomes more likely...

Страница 13: ...tal limits are applicable to the BarbLock Assembly Tool Use Conditions Storage Transport Conditions Temperature C 0 to 40 10 to 50 Altitude 0 to 6560 2000m 0 to 40 000 12 200m Relative Humidity 0 to 8...

Страница 14: ...35252AL BLTJAW005 PF135312PPAF AL BLTJAW006 BL135374 BLTJAW007 PF135375PPAF BLTJAW007 BL135375 BLTJAW007 BL135375AL BLTJAW007 BL135376 BLTJAW007 BL135377ALLRRPVDF BLTJAW007 BL135500 BLTJAW008 BL135500...

Страница 15: ...are visible in the right side Case Lift the right side Case off the tool along with its screws Figure 19 shows the appearance of the tool after removal of the right side Case Do not insert any hard or...

Страница 16: ...h the kit see figure 22 below Grease is injected into the carriage by inserting the tip of the type L fitting into the open end of the nipple on the end of the carriage shown in the red circle in figu...

Страница 17: ...the joint between the left and right side Cases to confirm that they are properly aligned with each other and the two Case halves are in contact Once this is confirmed insert the 8 screws that attach...

Страница 18: ...y to return to service 24 0 Troubleshooting If the Safety Cover the Latch or the jaws did not function as they should as described in the Functional Confir mation section or if an air leak was detecte...

Страница 19: ...ool Operations Manual www biopharm saint gobain com 19 FLS 5278C CLWR Rev 01 25 0 Tool Physical Details Tool Weight 5 2 pounds including one set of jaws Tool Dimensions refer to image below Figure 23...

Страница 20: ...BarbLock Assembly Tool Operations Manual www biopharm saint gobain com 20 FLS 5278C CLWR Rev 01 26 0 CE Mark Declaration Of Conformity...

Отзывы: