background image

BarbLock® Tabletop Pneumatic Assembly Tool: Operations Manual

www.biopharm.saint-gobain.com

3

FLS-5278C-CLWR-Rev 01

Read this before using the Saint-Gobain Performance Plastics BarbLock® Assembly Tool

 

We, as an authorized representative of Saint-Gobain of Williamsburg Michigan, USA certify and declare that the 
following BarbLock® Pneumatic Assembly Tool:

All users must read the entire BarbLock® Assembly Tool Operating Instructions before installing, using or main-
taining the tool. Always keep the Operating Instructions at hand when using the BarbLock® Assembly Tool. 

IMPORTANT:

 It is the user’s responsibility to ensure the suitability and safety of Saint-Gobain products for all 

intended uses and that the materials to be used comply with all applicable medical regulatory requirements. 
Saint-Gobain assumes no responsibility for any product failures that occur due to misuse arising out of the  
design, fabrication or application of the products into which the materials are incorporated. Saint-Gobain 
cannot assume liability if the BarbLock® Assembly Tool is subjected to improper use or operation. Saint-Gobain 
is not liable for any damages resulting therefrom. The operator bears the sole risk. Proper use also includes 
compliance with operating, inspection, and maintenance conditions prescribed by the manufacturer. Non-com-
pliance with the warnings in the operating instructions and installation instructions, in particular, constitutes 
improper use of the equipment. 

There is only one user serviceable parts inside the Tool, described in the section beginning on page 19.  
Accessing the inside of the tool for any other reason may void the warranty. Contact Saint-Gobain Performance 
Plastics if the product fails to operate correctly. Do not continue to use a product that is not operating correctly, 
as this could result in injury to the operator or others, or damage to the product. 

Intended Use

 

The BarbLock® Assembly Tool was exclusively developed, constructed, and built for the industrial and com-
mercial purpose of closing/locking the BarbLock® and Pure-Fit® SIB® retainers on a barbed fitting and flexible 
tubing connection using pneumatic power. The BarbLock® Assembly Tool shall not be used in any clinical proce-
dures, or for diagnostic purposes. The system is exclusively designed for the purpose stated above. Any other
application above or beyond this, or any modifications to the unit without the written permission of the manu-
facturer, is considered as improper use of the device, which could result in injury to the user or damage to the 
tool.

1.0 Important Notice

Содержание BarbLock BLT-HHPAD

Страница 1: ...Saint Gobain BarbLock Assembly Tool Part Number BLT HHPAD OPERATIONS MANUAL www biopharm saint gobain com...

Страница 2: ...Assembly Tool 9 Air Supply Connection 11 Operational and Safety Checks 12 Noise Emissions 12 Vibration 12 Tool Balance Connection and Use 12 Residual Risks 13 Use and Storage Conditions 13 Cleaning 1...

Страница 3: ...sole risk Proper use also includes compliance with operating inspection and maintenance conditions prescribed by the manufacturer Non com pliance with the warnings in the operating instructions and i...

Страница 4: ...nnec tion This creates an ultra secure connection that is more resistant to leakage than any other available technology Figure 2 below shows some of the Saint Gobain products with which the BarbLock A...

Страница 5: ...Saint Gobain brand name and symbol Figure 3 2 Product identification and company information Figure 4 3 This User Operator manual contains critical information that must be understood by the user in o...

Страница 6: ...rved the tool should be disconnected from the air supply and removed from the work area When the jaws are in the closed position a pinch risk is present in gaps just below the lower jaw see Figure 11...

Страница 7: ...will move any time the Safety Cover is closed and the trigger is pressed Keep fingers away from all openings in the area of the jaws Failure to do so could result in a serious pinching injury to the f...

Страница 8: ...not present in this image Jaw tail Figure 14 Example of Upper Jaw showing part number with suffix letter A to indicate upper position Jaws are installed in their respective carriers A suffix on the J...

Страница 9: ...ed to the tool This will happen no matter if the Safety Cover is closed or not Be aware of the possibility that the lower jaw carrier may move while connecting the tool to the pressurized air supply K...

Страница 10: ...o need for the operator to provide intervention to the BarbLock assembly WARNING Pinch Hazard after the BarbLock has fully closed the operator can release the Trigger This will cause the jaws to retra...

Страница 11: ...smaller sizes of BarbLocks as long as full closure of the BarbLocks is consistently achieved Pressure should be adjusted as needed to achieve full closure of the BarbLocks in use at the time The User...

Страница 12: ...nting motion of the jaws any time the Safety Cover is open If the Safety Cover interlock switch is defeated then the jaws can move while the Safety Cover is open and a pinch injury becomes more likely...

Страница 13: ...tal limits are applicable to the BarbLock Assembly Tool Use Conditions Storage Transport Conditions Temperature C 0 to 40 10 to 50 Altitude 0 to 6560 2000m 0 to 40 000 12 200m Relative Humidity 0 to 8...

Страница 14: ...35252AL BLTJAW005 PF135312PPAF AL BLTJAW006 BL135374 BLTJAW007 PF135375PPAF BLTJAW007 BL135375 BLTJAW007 BL135375AL BLTJAW007 BL135376 BLTJAW007 BL135377ALLRRPVDF BLTJAW007 BL135500 BLTJAW008 BL135500...

Страница 15: ...are visible in the right side Case Lift the right side Case off the tool along with its screws Figure 19 shows the appearance of the tool after removal of the right side Case Do not insert any hard or...

Страница 16: ...h the kit see figure 22 below Grease is injected into the carriage by inserting the tip of the type L fitting into the open end of the nipple on the end of the carriage shown in the red circle in figu...

Страница 17: ...the joint between the left and right side Cases to confirm that they are properly aligned with each other and the two Case halves are in contact Once this is confirmed insert the 8 screws that attach...

Страница 18: ...y to return to service 24 0 Troubleshooting If the Safety Cover the Latch or the jaws did not function as they should as described in the Functional Confir mation section or if an air leak was detecte...

Страница 19: ...ool Operations Manual www biopharm saint gobain com 19 FLS 5278C CLWR Rev 01 25 0 Tool Physical Details Tool Weight 5 2 pounds including one set of jaws Tool Dimensions refer to image below Figure 23...

Страница 20: ...BarbLock Assembly Tool Operations Manual www biopharm saint gobain com 20 FLS 5278C CLWR Rev 01 26 0 CE Mark Declaration Of Conformity...