27
3410330_GB
CONTROL AND SAFETY SYSTEMS
The following information concerns skilled staff only.
▪
Door micro-switch:
Prevents the appliance from working when the door is open
▪
Overall protection fuses:
Protect the whole power circuit from and short-circuits and
overloads
▪
Compressor thermal relay:
Operates in case of an overload or working failures
▪
Bimetallic safety thermostat:
intervenes in the event of excessively high temperature
in the inside compartment.
▪
Fan Motor Protector:
intervenes in the event of overload or malfunction.
▪
Safety pressure-switch:
Operates in case of coolant over-pressure
▪
Cabinet temperature control:
Is run by NTC probe through the relevant electronic card
▪
Core temperature control:
Is run by PT100 probe through an electronic card
▪
Electronic boards:
based on the parameters entered they command and control any
devices connected to the equipment.
Содержание 101L Series
Страница 21: ...21 3410330_GB DIMENSIONS Please refer to the dimensions of your own appliance...
Страница 51: ...51 3410330_GB CYCLE INFO Information on the current cycle can be displayed...
Страница 73: ...73 3410330_GB When nozzle maintenance is complete select settings water data to reset the number of injections...