Configuration methods
82 SAGEM
RT3000
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
15.2
Remote configuration by SMS
You may change the file
para.ini
with a configuration SMS. You have to send a SMS to
the SAGEM RT3000 from a remote location. You can configure up to 5 remote stations
that are allowed to send a configuration SMS (see
Settings for the configuration access
via SMS and FTP
, page 85).
!
The character “_” occuring in section names has to be replaced by space character.
Example:
#5000000CALL MUX,VOICE ALERT,B#
The SMS has to be in the following format:
#5 000000 SECTION,PARA,XX #
#5
The command prefix informs the device that a configuration
setting is to be made.
000000
The DEVICE PASSWORT protects your configuration against
intervention by others.
The command prefix and the access code together ensure that
accidental incorrect inputs do not change your configuration.
SECTION
this specifies the section of the
para.ini
to which the parameter
belongs to.
(
_
occurring in section names has to be replaced by space
character.)
,
separator
PARA
this specifies the parameter of the
para.ini
you wish to set.
( _ occurring in parameter names has to be replaced by space
character)
,
separator
XX
These 2 characters or digits (alphanumeric) set the new value
for this parameter.
#
This character is the signal that the command ends here.
!
The section and parameter you want to change have to exist in the
para.ini
file.
!
Configuration by SMS is only possible if in the section [DEVICE_ACCESS] the
parameter SMS_CONFIG=YES is set (Default).