Parameters in the file para.ini: advanced configuration
SAGEM RT3000
95
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
The minimum flash
duration. Shorter pulses
may be interpreted as
parts of pulse-dial! (10ms)
CHB_FLASH_MIN
4 - 55
7
The maximum flash
duration. Longer pulses
may be interpreted an
onhook/offhook! (10ms)
CHB_FLASH_MAX
12 - 65
50
16.15 RING frequency
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
The frequency of the RING signal can be selected between 25Hz and 50Hz.
CHA_HIGH_RING_FREQ defines the RING frequency for the Telephone port.
CHB_HIGH_RING_FREQ defines the RING frequency for the Telephone port.
If the setting is NO, the RING frequency is 25Hz.
Section:
RING
Meaning Parameter Permitted
Values
Factory Setting
Ring 50Hz (else 25Hz)
CHA_HIGH_RING_FREQ YES, NO
NO
Ring 50Hz (else 25Hz)
CHB_HIGH_RING_FREQ YES, NO
NO
16.16 Dialling configuration
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Fast Dialling
Normally you must enter the telephone number completely before the SAGEM RT3000
can start dialling. The SAGEM RT3000 starts dialling until you do not press any more
key on the telephone and after the
dial timeout
is expired - the duration the SAGEM
RT3000 waits for any new key stroke.
If the function
Fast Dialling
is enabled, the SAGEM RT3000 starts dialling immediately
when you terminate the dial sequence by pressing the
Fast Dialling Key
: a
#
.
For example: 00331234567#.